109 lines
4.3 KiB
CSV
109 lines
4.3 KiB
CSV
Column_1,Column_2
|
|
APPLICABLE CODES:,"GENERAL:
|
|
• BUILDING/DWELLING CODE IBC 2015 & AHJ AMENDMENTS
|
|
EXISTING:
|
|
• INTERNATIONAL EXISTING BUILDING CODE 2015 & AHJ AMENDMENTS
|
|
ENERGY CONSERVATION:
|
|
• INTERNATIONAL ENERGY CONSERVATION CODE 2015 & AHJ AMENDMENTS
|
|
PLUMBING:
|
|
WISCONSIN ADMINISTRATIVE CODE, SPS 380-387
|
|
MECHANICAL:
|
|
• INTERNATIONAL MECHANICAL CODE IMC 2015 & AHJ AMENDMENTS
|
|
ELECTRICAL:
|
|
• INTERNATIONAL ELECTRICAL CODE NEC 2017 & AHJ AMENDMENTS
|
|
FIRE:
|
|
• INTERNATIONAL FIRE/LIFE SAFETY CODE 2009 NFPA-1 & AHJ AMENDMENTS
|
|
FUEL:
|
|
• INTERNATIONAL FUEL GAS CODE 2015 & AHJ AMENDMENTS
|
|
ACCESSIBILITY:
|
|
• ANSI STANDARD A117.1-2009- FOR ACCESSIBILITY
|
|
"
|
|
IBC - CHAPTER 3 USE AND OCCUPANCY CLASSIFICATION:,304.1 BUSINESS GROUP B
|
|
IBC - CHAPTER 5 CLASSIFICATION OF WORK:,ALTERATION—LEVEL 2
|
|
IBC - 504.3 HEIGHT IN FEET,"FOR TYPE VB:
|
|
• ACTUAL: 30FT
|
|
• ALLOWED: 40FT"
|
|
IBC - 504.4 NUMBER OF STORIES,"• ACTUAL: 2
|
|
• ALLOWED: 2
|
|
"
|
|
"IBC - 506.2 ALLOWABLE AREA DETERMINATION
|
|
&
|
|
506.3 FRONTAGE INCREASE:","1. TABULAR PER FLOOR AREA LIMIT PER CHAPTER 5 = 9000 SQ.FT.
|
|
2. ALLOW HEIGHT = 40 FT; ALLOW STORIES = 2
|
|
- GROUP R AND NFPA 13R? NO
|
|
- NFPA 13 SPRINKLERS? NO
|
|
3. COMPUTE AREA INCREASE DUE TO FRONTAGE: FRONTAGE COEFFICIENT, IF = 0.444
|
|
- PERIMETER, P = 366 FT
|
|
- 'FRONTAGE' PERIMETER, F = 267 FT
|
|
- WEIGHTED AVERAGE DISTANCE FROM 'F' = 27.8 FT
|
|
4. COMPUTE ALLOWABLE PER STORY AREA, AA = AT +(NS X IF) = 12998.78 SQ.FT.
|
|
5. MAXIMUM ALLOWABLE AREA = AA X 2 = 25997.55 SQ.FT.
|
|
6. MAXIMUM NUMBER OF STORIES FOR GROUP R WITH NFPA 13R SPRINKLERS, PER SEC. 903.3.1.2. THIS CRITERIA IS NOT MET, SO STORY LIMIT = 2
|
|
7. THE REVISED ALLOWABLE HEIGHT IS 40 FT."
|
|
IBC - 508.3 NONSEPARATED OCCUPANCIES:,YES - GROUP B
|
|
IBC - 508.4 SEPARATED OCCUPANCIES,NO
|
|
"IBC - TABLE 601
|
|
FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (HOURS)","FOR TYPE VB
|
|
STRUCTURAL FRAME: 0 HR
|
|
BEARING WALLS- EXTERIOR: 0 HR
|
|
BEARING WALLS-INTERIOR: 0 HR
|
|
NON-BEARING WALLS-EXTERIOR - (SEE TABLE 602)
|
|
NON-BEARING WALLS-INTERIOR: 0 HR
|
|
FLOOR CONSTRUCTION: 0 HR
|
|
ROOF CONSTRUCTION: 0 HR
|
|
"
|
|
"IBC - TABLE 602
|
|
FIRE-RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE SEPARATION DISTANCE","TYPE-VB
|
|
|
|
FIRE SEPARATION DISTANCE
|
|
• X < 5C = 1 HR
|
|
• 5 ≤ X ≤ 10 = 1 HR
|
|
• 10 ≤ X ≤ 30 = 0 HR
|
|
• X ≥ 30 = 0 HR"
|
|
IBC - 803.11 INTERIOR FINISH REQUIREMENTS BASED ON GROUP,"FOR SPRINKLERED (B)
|
|
INTERIOR EXIT STAIRWAYS AND RAMPS AND EXIT PASSAGEWAYS: CLASS B
|
|
CORRIDORS AND ENCLOSURE FOR EXIT ACCESS STAIRWAYS AND RAMPS: CLASS C
|
|
ROOMS AND ENCLOSED: CLASS C"
|
|
IBC - SPRINKLERS (SECTION 903 AUTOMATIC SPRINKLER SYSTEMS):,NO SPRINKLERS
|
|
IBC - TABLE 906.3(1) FIRE EXTINGUISHERS FOR CLASS A FIRE HAZARDS ,"TYPE 2-A:
|
|
• (EVERYWHERE EXCEPT KITCHEN)
|
|
• MAXIMUM FLOOR AREA PER UNIT OF A: 1,500SF
|
|
• MAXIMUM FLOOR AREA FOR EXTINGUISHER: 11,250SF
|
|
• MAXIMUM DISTANCE TO EXTINGUISHER: 75FT
|
|
• HAZARD CLASSIFICATION: ORDINARY (MODERATE) HAZARD OCCUPANCY
|
|
|
|
|
|
TYPE K:
|
|
• 2.5-GALLON OR (2)1.5-GALLON
|
|
• MAXIMUM DISTANCE TO EXTINGUISHER:WITHIN 30FT OF COOKING EQUIPMENT
|
|
• HAZARD CLASSIFICATION:ORDINARY (MODERATE)"
|
|
IBC - SECTION 907 FIRE ALARM AND DETECTION SYSTEMS,"FIRE ALARM IS NOT REQUIRED, BUT ONE IS CURRENTLY INSTALLED"
|
|
IBC - SECTION 1004 OCCUPANT LOAD,SEE OCCUPANT LOAD SCHEDULE
|
|
,
|
|
IBC - SECTION 1020 CORRIDORS,"CORRIDORS: 0 HR RATED
|
|
A FIRE-RESISTANCE RATING IS NOT REQUIRED FOR CORRIDORS IN AN OCCUPANCY IN GROUP B THAT IS A SPACE REQUIRING ONLY A SINGLE MEANS OF EGRESS COMPLYING WITH SECTION 1006.2."
|
|
,
|
|
IBC - 1006.2.1 EGRESS BASED ON OCCUPANT LOAD AND COMMON PATH OF EGRESS TRAVEL DISTANCE:,"FOR (F, S, B)
|
|
MAXIMUM COMMON PATH WITHOUT SPRINKLER SYSTEM: 75FT
|
|
MAXIMUM OCCUPANT LOAD OF SPACE WITH ONE EXIT: 49
|
|
|
|
"
|
|
IBC - SECTION 1017 EXIT ACCESS TRAVEL DISTANCE:,"FOR B: 300 FT (W/SPRINKLER)
|
|
|
|
"
|
|
"IBC - 1020.4 DEAD ENDS OR
|
|
IEBC - 805.6 DEAD-END CORRIDORS",35 FEET PER IEBC - 805.6
|
|
2902.1 MINIMUM NUMBER OF FIXTURES,"CLASSIFICATION & OCCUPANCY:
|
|
|
|
A-2: RESTAURANTS, BANQUET
|
|
HALLS AND FOOD COURTS
|
|
TOTAL OCCUPANTS: 83
|
|
FEMALE OCCUPANTS: 42
|
|
FEMALE OCCUPANTS: 42
|
|
• WATER CLOSETS: 1 PER 75
|
|
• WOMEN: 0.56 = 1 REQUIRED (1 PROVIDED)
|
|
• MEN: 0.56 = 1 REQUIRED (1 PROVIDED)
|
|
• LAVATORIES: 1 PER 200
|
|
• WOMEN: 0.21 = 1 REQUIRED (1 PROVIDED)
|
|
• MEN: 0.21 = 1 REQUIRED (1 PROVIDED)
|
|
• SERVICE SINK: 1 REQUIRED (1 PROVIDED)"
|