Restaurant_Whitefish_Bay/Models and CAD/Schedules/Code Information.csv

109 lines
4.3 KiB
CSV

Column_1,Column_2
APPLICABLE CODES:,"GENERAL:
• BUILDING/DWELLING CODE IBC 2015 & AHJ AMENDMENTS
EXISTING:
• INTERNATIONAL EXISTING BUILDING CODE 2015 & AHJ AMENDMENTS
ENERGY CONSERVATION:
• INTERNATIONAL ENERGY CONSERVATION CODE 2015 & AHJ AMENDMENTS
PLUMBING:
WISCONSIN ADMINISTRATIVE CODE, SPS 380-387
MECHANICAL:
• INTERNATIONAL MECHANICAL CODE IMC 2015 & AHJ AMENDMENTS
ELECTRICAL:
• INTERNATIONAL ELECTRICAL CODE NEC 2017 & AHJ AMENDMENTS
FIRE:
• INTERNATIONAL FIRE/LIFE SAFETY CODE 2009 NFPA-1 & AHJ AMENDMENTS
FUEL:
• INTERNATIONAL FUEL GAS CODE 2015 & AHJ AMENDMENTS
ACCESSIBILITY:
• ANSI STANDARD A117.1-2009- FOR ACCESSIBILITY
"
IBC - CHAPTER 3 USE AND OCCUPANCY CLASSIFICATION:,304.1 BUSINESS GROUP B
IBC - CHAPTER 5 CLASSIFICATION OF WORK:,ALTERATION—LEVEL 2
IBC - 504.3 HEIGHT IN FEET,"FOR TYPE VB:
• ACTUAL: 30FT
• ALLOWED: 40FT"
IBC - 504.4 NUMBER OF STORIES,"• ACTUAL: 2
• ALLOWED: 2
"
"IBC - 506.2 ALLOWABLE AREA DETERMINATION
&
506.3 FRONTAGE INCREASE:","1. TABULAR PER FLOOR AREA LIMIT PER CHAPTER 5 = 9000 SQ.FT.
2. ALLOW HEIGHT = 40 FT; ALLOW STORIES = 2
- GROUP R AND NFPA 13R? NO
- NFPA 13 SPRINKLERS? NO
3. COMPUTE AREA INCREASE DUE TO FRONTAGE: FRONTAGE COEFFICIENT, IF = 0.444
- PERIMETER, P = 366 FT
- 'FRONTAGE' PERIMETER, F = 267 FT
- WEIGHTED AVERAGE DISTANCE FROM 'F' = 27.8 FT
4. COMPUTE ALLOWABLE PER STORY AREA, AA = AT +(NS X IF) = 12998.78 SQ.FT.
5. MAXIMUM ALLOWABLE AREA = AA X 2 = 25997.55 SQ.FT.
6. MAXIMUM NUMBER OF STORIES FOR GROUP R WITH NFPA 13R SPRINKLERS, PER SEC. 903.3.1.2. THIS CRITERIA IS NOT MET, SO STORY LIMIT = 2
7. THE REVISED ALLOWABLE HEIGHT IS 40 FT."
IBC - 508.3 NONSEPARATED OCCUPANCIES:,YES - GROUP B
IBC - 508.4 SEPARATED OCCUPANCIES,NO
"IBC - TABLE 601
FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (HOURS)","FOR TYPE VB
STRUCTURAL FRAME: 0 HR
BEARING WALLS- EXTERIOR: 0 HR
BEARING WALLS-INTERIOR: 0 HR
NON-BEARING WALLS-EXTERIOR - (SEE TABLE 602)
NON-BEARING WALLS-INTERIOR: 0 HR
FLOOR CONSTRUCTION: 0 HR
ROOF CONSTRUCTION: 0 HR
"
"IBC - TABLE 602
FIRE-RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE SEPARATION DISTANCE","TYPE-VB
FIRE SEPARATION DISTANCE
• X < 5C = 1 HR
• 5 ≤ X ≤ 10 = 1 HR
• 10 ≤ X ≤ 30 = 0 HR
• X ≥ 30 = 0 HR"
IBC - 803.11 INTERIOR FINISH REQUIREMENTS BASED ON GROUP,"FOR SPRINKLERED (B)
INTERIOR EXIT STAIRWAYS AND RAMPS AND EXIT PASSAGEWAYS: CLASS B
CORRIDORS AND ENCLOSURE FOR EXIT ACCESS STAIRWAYS AND RAMPS: CLASS C
ROOMS AND ENCLOSED: CLASS C"
IBC - SPRINKLERS (SECTION 903 AUTOMATIC SPRINKLER SYSTEMS):,NO SPRINKLERS
IBC - TABLE 906.3(1) FIRE EXTINGUISHERS FOR CLASS A FIRE HAZARDS ,"TYPE 2-A:
• (EVERYWHERE EXCEPT KITCHEN)
• MAXIMUM FLOOR AREA PER UNIT OF A: 1,500SF
• MAXIMUM FLOOR AREA FOR EXTINGUISHER: 11,250SF
• MAXIMUM DISTANCE TO EXTINGUISHER: 75FT
• HAZARD CLASSIFICATION: ORDINARY (MODERATE) HAZARD OCCUPANCY
TYPE K:
• 2.5-GALLON OR (2)1.5-GALLON
• MAXIMUM DISTANCE TO EXTINGUISHER:WITHIN 30FT OF COOKING EQUIPMENT
• HAZARD CLASSIFICATION:ORDINARY (MODERATE)"
IBC - SECTION 907 FIRE ALARM AND DETECTION SYSTEMS,"FIRE ALARM IS NOT REQUIRED, BUT ONE IS CURRENTLY INSTALLED"
IBC - SECTION 1004 OCCUPANT LOAD,SEE OCCUPANT LOAD SCHEDULE
,
IBC - SECTION 1020 CORRIDORS,"CORRIDORS: 0 HR RATED
A FIRE-RESISTANCE RATING IS NOT REQUIRED FOR CORRIDORS IN AN OCCUPANCY IN GROUP B THAT IS A SPACE REQUIRING ONLY A SINGLE MEANS OF EGRESS COMPLYING WITH SECTION 1006.2."
,
IBC - 1006.2.1 EGRESS BASED ON OCCUPANT LOAD AND COMMON PATH OF EGRESS TRAVEL DISTANCE:,"FOR (F, S, B)
MAXIMUM COMMON PATH WITHOUT SPRINKLER SYSTEM: 75FT
MAXIMUM OCCUPANT LOAD OF SPACE WITH ONE EXIT: 49
"
IBC - SECTION 1017 EXIT ACCESS TRAVEL DISTANCE:,"FOR B: 300 FT (W/SPRINKLER)
"
"IBC - 1020.4 DEAD ENDS OR
IEBC - 805.6 DEAD-END CORRIDORS",35 FEET PER IEBC - 805.6
2902.1 MINIMUM NUMBER OF FIXTURES,"CLASSIFICATION & OCCUPANCY:
A-2: RESTAURANTS, BANQUET
HALLS AND FOOD COURTS
TOTAL OCCUPANTS: 83
FEMALE OCCUPANTS: 42
FEMALE OCCUPANTS: 42
• WATER CLOSETS: 1 PER 75
• WOMEN: 0.56 = 1 REQUIRED (1 PROVIDED)
• MEN: 0.56 = 1 REQUIRED (1 PROVIDED)
• LAVATORIES: 1 PER 200
• WOMEN: 0.21 = 1 REQUIRED (1 PROVIDED)
• MEN: 0.21 = 1 REQUIRED (1 PROVIDED)
• SERVICE SINK: 1 REQUIRED (1 PROVIDED)"