2APPLICABLE CODES:GENERAL: • BUILDING/DWELLING CODE IBC 2015 & AHJ AMENDMENTS EXISTING: • INTERNATIONAL EXISTING BUILDING CODE 2015 & AHJ AMENDMENTS ENERGY CONSERVATION: • INTERNATIONAL ENERGY CONSERVATION CODE 2015 & AHJ AMENDMENTS PLUMBING: WISCONSIN ADMINISTRATIVE CODE, SPS 380-387 MECHANICAL: • INTERNATIONAL MECHANICAL CODE IMC 2015 & AHJ AMENDMENTS ELECTRICAL: • INTERNATIONAL ELECTRICAL CODE NEC 2017 & AHJ AMENDMENTS FIRE: • INTERNATIONAL FIRE/LIFE SAFETY CODE 2009 NFPA-1 & AHJ AMENDMENTS FUEL: • INTERNATIONAL FUEL GAS CODE 2015 & AHJ AMENDMENTS ACCESSIBILITY: • ANSI STANDARD A117.1-2009- FOR ACCESSIBILITY
3IBC - CHAPTER 3 USE AND OCCUPANCY CLASSIFICATION:304.1 BUSINESS GROUP B
4IBC - CHAPTER 5 CLASSIFICATION OF WORK:ALTERATION—LEVEL 2
5IBC - 504.3 HEIGHT IN FEETFOR TYPE VB: • ACTUAL: 30FT • ALLOWED: 40FT
6IBC - 504.4 NUMBER OF STORIES• ACTUAL: 2 • ALLOWED: 2
7IBC - 506.2 ALLOWABLE AREA DETERMINATION & 506.3 FRONTAGE INCREASE:1. TABULAR PER FLOOR AREA LIMIT PER CHAPTER 5 = 9000 SQ.FT. 2. ALLOW HEIGHT = 40 FT; ALLOW STORIES = 2 - GROUP R AND NFPA 13R? NO - NFPA 13 SPRINKLERS? NO 3. COMPUTE AREA INCREASE DUE TO FRONTAGE: FRONTAGE COEFFICIENT, IF = 0.444 - PERIMETER, P = 366 FT - 'FRONTAGE' PERIMETER, F = 267 FT - WEIGHTED AVERAGE DISTANCE FROM 'F' = 27.8 FT 4. COMPUTE ALLOWABLE PER STORY AREA, AA = AT +(NS X IF) = 12998.78 SQ.FT. 5. MAXIMUM ALLOWABLE AREA = AA X 2 = 25997.55 SQ.FT. 6. MAXIMUM NUMBER OF STORIES FOR GROUP R WITH NFPA 13R SPRINKLERS, PER SEC. 903.3.1.2. THIS CRITERIA IS NOT MET, SO STORY LIMIT = 2 7. THE REVISED ALLOWABLE HEIGHT IS 40 FT.
8IBC - 508.3 NONSEPARATED OCCUPANCIES:YES - GROUP B
9IBC - 508.4 SEPARATED OCCUPANCIESNO
10IBC - TABLE 601 FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (HOURS)FOR TYPE VB STRUCTURAL FRAME: 0 HR BEARING WALLS- EXTERIOR: 0 HR BEARING WALLS-INTERIOR: 0 HR NON-BEARING WALLS-EXTERIOR - (SEE TABLE 602) NON-BEARING WALLS-INTERIOR: 0 HR FLOOR CONSTRUCTION: 0 HR ROOF CONSTRUCTION: 0 HR
11IBC - TABLE 602 FIRE-RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE SEPARATION DISTANCETYPE-VB FIRE SEPARATION DISTANCE • X < 5C = 1 HR • 5 ≤ X ≤ 10 = 1 HR • 10 ≤ X ≤ 30 = 0 HR • X ≥ 30 = 0 HR
12IBC - 803.11 INTERIOR FINISH REQUIREMENTS BASED ON GROUPFOR SPRINKLERED (B) INTERIOR EXIT STAIRWAYS AND RAMPS AND EXIT PASSAGEWAYS: CLASS B CORRIDORS AND ENCLOSURE FOR EXIT ACCESS STAIRWAYS AND RAMPS: CLASS C ROOMS AND ENCLOSED: CLASS C
13IBC - SPRINKLERS (SECTION 903 AUTOMATIC SPRINKLER SYSTEMS):NO SPRINKLERS
14IBC - TABLE 906.3(1) FIRE EXTINGUISHERS FOR CLASS A FIRE HAZARDS TYPE 2-A: • (EVERYWHERE EXCEPT KITCHEN) • MAXIMUM FLOOR AREA PER UNIT OF A: 1,500SF • MAXIMUM FLOOR AREA FOR EXTINGUISHER: 11,250SF • MAXIMUM DISTANCE TO EXTINGUISHER: 75FT • HAZARD CLASSIFICATION: ORDINARY (MODERATE) HAZARD OCCUPANCY TYPE K: • 2.5-GALLON OR (2)1.5-GALLON • MAXIMUM DISTANCE TO EXTINGUISHER:WITHIN 30FT OF COOKING EQUIPMENT • HAZARD CLASSIFICATION:ORDINARY (MODERATE)
15IBC - SECTION 907 FIRE ALARM AND DETECTION SYSTEMSFIRE ALARM IS NOT REQUIRED, BUT ONE IS CURRENTLY INSTALLED
16IBC - SECTION 1004 OCCUPANT LOADSEE OCCUPANT LOAD SCHEDULE
17
18IBC - SECTION 1020 CORRIDORSCORRIDORS: 0 HR RATED A FIRE-RESISTANCE RATING IS NOT REQUIRED FOR CORRIDORS IN AN OCCUPANCY IN GROUP B THAT IS A SPACE REQUIRING ONLY A SINGLE MEANS OF EGRESS COMPLYING WITH SECTION 1006.2.
19
20IBC - 1006.2.1 EGRESS BASED ON OCCUPANT LOAD AND COMMON PATH OF EGRESS TRAVEL DISTANCE:FOR (F, S, B) MAXIMUM COMMON PATH WITHOUT SPRINKLER SYSTEM: 75FT MAXIMUM OCCUPANT LOAD OF SPACE WITH ONE EXIT: 49
21IBC - SECTION 1017 EXIT ACCESS TRAVEL DISTANCE:FOR B: 300 FT (W/SPRINKLER)
22IBC - 1020.4 DEAD ENDS OR IEBC - 805.6 DEAD-END CORRIDORS35 FEET PER IEBC - 805.6
232902.1 MINIMUM NUMBER OF FIXTURESCLASSIFICATION & OCCUPANCY: A-2: RESTAURANTS, BANQUET HALLS AND FOOD COURTS TOTAL OCCUPANTS: 83 FEMALE OCCUPANTS: 42 FEMALE OCCUPANTS: 42 • WATER CLOSETS: 1 PER 75 • WOMEN: 0.56 = 1 REQUIRED (1 PROVIDED) • MEN: 0.56 = 1 REQUIRED (1 PROVIDED) • LAVATORIES: 1 PER 200 • WOMEN: 0.21 = 1 REQUIRED (1 PROVIDED) • MEN: 0.21 = 1 REQUIRED (1 PROVIDED) • SERVICE SINK: 1 REQUIRED (1 PROVIDED)