| 1 | Column_1 | Column_2 | Column_3 | Column_4 |
|---|---|---|---|---|
| 2 | Applicable Codes: | |||
| 3 | General: | Building/Dwelling Code IBC 2009 (WI Commercial Building Code SPS 362) | ||
| 4 | Existing: | International Existing Building Code 2009 (WI Commercial Building Code SPS 366) | ||
| 5 | Energy Conservation: | International Energy Conservation Code 2009 (WI Commercial Building Code v363) | ||
| 6 | Plumbing: | International Plumbing Code (WI Commercial Building Code SPS 381-387) | ||
| 7 | Mechanical: | Mechanical Code IMC 2009 (WI Commercial Building Code SPS 364) | ||
| 8 | Electrical | Electrical Code NEC 2008(WI Commercial Building Code SPS 316 | ||
| 9 | Fire: | Fire/Life Safety Code 2009 NFPA-1 (WI Commercial Building Code SPS 314 & 330) | ||
| 10 | Accessibility: | ANSI Standard A117.1-2009- for Accessibility (WI Commercial Building Code SPS 362) | ||
| 11 | Fuel: | International Fuel Gas Code 2009 (WI Commercial Building Code Chapter 365) | ||
| 12 | Sprinklers: | No | https://up.codes/viewer/alabama/int_building_code_2009/chapter/9/fire-protection-systems#903 | |
| 13 | Basement: | No Basement | ||
| 14 | Alteration Level (IEBC 405): | Level 2 | https://up.codes/viewer/pennsylvania/int_ebc_2009/chapter/4/classification-of-work#404 | |
| 15 | Occupancy Types (302.1): | Factory Industrial F-2 Low-Hazard Occupancy | https://up.codes/viewer/alabama/int_building_code_2009/chapter/3/use-and-occupancy-classification#302 | |
| 16 | Business Group B | |||
| 17 | Type of Construction: | TYPE III-B | https://up.codes/viewer/alabama/int_building_code_2009/chapter/6/types-of-construction#602 | |
| 18 | Number of Stories | 1 Story (w/ Mezzanine) | ||
| 19 | SECTION 506 BUILDING AREA MODIFICATIONS | https://up.codes/viewer/alabama/int_building_code_2009/chapter/5/general-building-heights-and-areas#506 | ||
| 20 | Building perimeter lengths (ft) | Distance to property line or to far side of R.O.W. (ft) | ||
| 21 | facing north: | 431 | 60+ | |
| 22 | facing east: | 250 | 60+ | |
| 23 | facing south: | 431 | 60+ | |
| 24 | facing west: | 123 | 17 | |
| 25 | 79 | 41 | ||
| 26 | 49 | 60+ | ||
| 27 | ||||
| 28 | Allowable Areas and Heights Type IIIB Factory (F-2) Occupancy | |||
| 29 | Allowable area per floor: | 41249 sq.ft. | ||
| 30 | Total allowable area: | 41249 sq.ft. | ||
| 31 | Maximum allowable height: | 55 ft. | ||
| 32 | Maximum allowable stories: | 3 | ||
| 33 | ||||
| 34 | Allowable Areas and Heights Type IIIB Business (B) Occupancy | Allowable area per floor: | 31523 sq.ft. | |
| 35 | Total allowable area: | 31523 sq.ft. | ||
| 36 | Maximum allowable height: | 55 ft. | ||
| 37 | Maximum allowable stories: | 3 | ||
| 38 | TABLE 601- FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (hours) | Structural Frame: | 0 hr | https://up.codes/viewer/alabama/int_building_code_2009/chapter/6/types-of-construction#602.1 |
| 39 | Bearing Walls- exterior: | 2 hr | ||
| 40 | Bearing Walls-interior: | 0 hr | ||
| 41 | Non-bearing walls-exterior - Fire Separation Distance | |||
| 42 | X < 5c = 1 hr | |||
| 43 | 5 = X< 10 = 1 hr | |||
| 44 | 10 = X< 30 = 1 hr | |||
| 45 | X = 30 = 0 hr | |||
| 46 | Non-bearing walls-interior: | 0 hr | ||
| 47 | Floor Construction: | 0 hr | ||
| 48 | Roof Construction: | 0 hr | ||
| 49 | ||||
| 50 | Corridor Fire Resistance Rating (Table 1018.1) | 1 hr without Sprinklers | https://up.codes/viewer/alabama/int_building_code_2009/chapter/10/means-of-egress#1018 | |
| 51 | Common Path of Egress Travel: (1014.3) | 75 | https://up.codes/viewer/alabama/int_building_code_2009/chapter/10/means-of-egress#1014.3 | |
| 52 | Maximum Travel Distance: (1016.1) | B: 200ft | https://up.codes/viewer/alabama/int_building_code_2009/chapter/10/means-of-egress#1016 | |
| 53 | F-2: 300ft | |||
| 54 | Min. number of exits less than 500 (Table 1015.1 & Table 1021.1) | 2 | https://up.codes/viewer/alabama/int_building_code_2009/chapter/10/means-of-egress#1015 | |
| 55 | Dead end corridor max. length | Existing (IEBC 805.6): 35ft | https://up.codes/viewer/wyoming/iebc-2015/chapter/8/alterations-level-2#805.6 | |
| 56 | New Construction (1018.4): 20ft | https://up.codes/viewer/alabama/ibc-2009/chapter/10/means-of-egress#1018.4 | ||
| 57 | Fire Extinguishers: | Type 2-A: (everywhere except kitchen) | https://up.codes/viewer/alabama/ibc-2009/chapter/9/fire-protection-systems#906.3 | |
| 58 | Maximum Floor Area Per Unit of A: | 1,500sf | ||
| 59 | Maximum Distance to Extinguisher: | 75ft | ||
| 60 | Hazard Classification: | Ordinary (Moderate) | ||
| 61 | ||||
| 62 | Type K: | |||
| 63 | 2.5-gallon or (2)1.5-gallon | |||
| 64 | Maximum Distance to Extinguisher: | Within 30ft of cooking equipment | ||
| 65 | Hazard Classification: | Ordinary (Moderate) |