PARTITION TAG NOMENCLATURE

Position Description Codes / Meanings
1ST POSITION Core Material W = Wood
E = Engineered Lumber
M = Metal
C = Concrete
B = Masonry Block
2ND POSITION Size of Core Wood: Nominal stud sizes (e.g. 4 = 3½”)
Engineered Lumber: (e.g. 4 = 3½”)
Metal Stud: e.g. 358 = 3⅝”
Concrete: Actual wall thickness (e.g. 8 = 8”)
Masonry: Nominal brick modules (e.g. 8 = 7⅝”)
3RD POSITION Layer Material See “Layer Material Codes” table below
4TH POSITION Fire Rating Ø = 0 Hour
1 = 1 Hour
2 = 2 Hour
3 = 3 Hour
5 = ½ Hour
5TH POSITION
(AND BEYOND)
Modifiers A = Partial height partition (Layers 14 terminate at/below hung ceiling)
B = Partial height partition (Layer 1 extends above ceiling; others 6" above ceiling)
C = Partial height partition (Layer 1 to structure; others 6" above ceiling)
D = Full height to underside of structural deck/sheathing
F = Full height to underside of structural floor/roof assembly
K = Knee wall partition
R = Furred-out wall

Layer Material Codes (3rd Position)

Code Layer 4-L Layer 3-L Layer 2-L Layer 1 (Core) Layer 2-R Layer 3-R Layer 4-R Details
& UL Number
A 5/8” Gyp. Bd. 2x wood studs 16" O.C. without batt insulation 5/8” Gyp. Bd. BASE: 5A/A100
HEAD: 4A/A100
B 5/8” Gyp. Bd. 2x wood studs 16" O.C. with batt insulation 5/8” Gyp. Bd. BASE: 5A/A100
HEAD: 4A/A100
C 5/8” Gyp. Bd. 2x wood studs 16" O.C. without batt insulation ¼” Air Gap

Example: M358CØFR

 ┌────┬──────┬────┬────┬────┬────┐
 │ M  │ 358  │ C  │ Ø  │ F  │ R  │
 └────┴──────┴────┴────┴────┴────┘
   │     │      │    │    │    └─ 6th: Furred Wall
   │     │      │    │    └────── 5th: Full Height To Underside Of Structure
   │     │      │    └─────────── 4th: 0 Hr Fire Rating
   │     │      └──────────────── 3rd: Gyp. Bd. On One Side W/ Batt Insulation
   │     └─────────────────────── 2nd: 3⅝" Metal Stud
   └───────────────────────────── 1st: Metal Stud Core