153 lines
16 KiB
XML
153 lines
16 KiB
XML
<?xml version="1.0" encoding="utf-8" ?>
|
||
<svg xmlns="http://www.w3.org/2000/svg" xmlns:ev="http://www.w3.org/2001/xml-events" xmlns:xlink="http://www.w3.org/1999/xlink" baseProfile="full" height="285.80943999999994mm" id="root" version="1.1" viewBox="0 0 201.90053999999998 285.80943999999994" width="201.90053999999998mm">
|
||
<defs>
|
||
<style type="text/css"><![CDATA[/*
|
||
* BlenderBIM Add-on - OpenBIM Blender Add-on
|
||
* Copyright (C) 2020, 2021 Dion Moult <dion@thinkmoult.com>
|
||
*
|
||
* This file is part of BlenderBIM Add-on.
|
||
*
|
||
* BlenderBIM Add-on is free software: you can redistribute it and/or modify
|
||
* it under the terms of the GNU General Public License as published by
|
||
* the Free Software Foundation, either version 3 of the License, or
|
||
* (at your option) any later version.
|
||
*
|
||
* BlenderBIM Add-on is distributed in the hope that it will be useful,
|
||
* but WITHOUT ANY WARRANTY, without even the implied warranty of
|
||
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
|
||
* GNU General Public License for more details.
|
||
*
|
||
* You should have received a copy of the GNU General Public License
|
||
* along with BlenderBIM Add-on. If not, see <http://www.gnu.org/licenses/>.
|
||
*/
|
||
|
||
/**
|
||
* You may copy this `schedule.css` template alongside your input schedule
|
||
* document with the same filename. For example if you have a schedule called
|
||
* `door_types.ods`, you can create a `door_types.css` in the same folder to
|
||
* style that schedule.
|
||
*/
|
||
|
||
/**
|
||
* If you specify a font size in CSS, such as text { font-size: 5; }, all fonts
|
||
* will be overriden to match that size.
|
||
*
|
||
* If your CSS, ODS, XLSX does not specify a font size, the variables below
|
||
* will specify the default font size.
|
||
*
|
||
* If your ODS, XLSX does specify a font size, they will scale linearly based
|
||
* on the variables below.
|
||
*/
|
||
|
||
:root {
|
||
--font-size-pt: 10.9;
|
||
--font-size-px: 3.65;
|
||
--font-width: 0.63;
|
||
}
|
||
|
||
text,
|
||
tspan {
|
||
/* 2.5mm */
|
||
fill: #2c5573 !important;
|
||
stroke: none !important;
|
||
font-family: "Century Gothic", "OpenGost Type B TT", "DejaVu Sans Condensed",
|
||
"Liberation Sans", "Arial Narrow", "Arial" !important;
|
||
}
|
||
|
||
.border {
|
||
stroke: #2c5573;
|
||
stroke-width: 0.3;
|
||
fill: none;
|
||
}
|
||
]]></style>
|
||
</defs>
|
||
<rect class="border" height="6.670039999999999" style="fill: #ffffff;" width="199.90053999999998" x="1" y="1"/>
|
||
<text dominant-baseline="hanging" fill="#406183" font-size="0" text-anchor="start">
|
||
<tspan dy="0em" fill="#406183" font-size="3.348623853211009" x="2" y="2">GENERAL NOTES</tspan>
|
||
</text>
|
||
<rect class="border" height="277.13939999999997" style="fill: #ffffff;" width="199.90053999999998" x="1" y="7.670039999999999"/>
|
||
<text dominant-baseline="hanging" fill="#406183" font-size="0" text-anchor="start">
|
||
<tspan dy="0em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● THE MECHANICAL (HVAC), ELECTRICAL, PLUMBING, FIRE PROTECTION, AND FIRE ALARM SYSTEMS WILL BE</tspan>
|
||
<tspan dy="1em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">DESIGNED AND CONSTRUCTED USING THE DESIGN-BUILD DELIVERY METHOD. THESE SPECIFIC DETAILS ARE</tspan>
|
||
<tspan dy="2em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">NOT PROVIDED IN THESE DOCUMENTS. IT IS THE RESPONSIBILITY OF THE M/E/P/FP/A CONTRACTOR TO</tspan>
|
||
<tspan dy="3em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">COORDINATE WITH THE GENERAL CONTRACTOR AND UTILIZE THESE DRAWINGS TO GUIDE THE FINAL DESIGN OF</tspan>
|
||
<tspan dy="4em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">THEIR SYSTEMS. ANY CHANGES TO THE STRUCTURE OR ARCHITECTURAL FEATURES MUST BE COMMUNICATED TO</tspan>
|
||
<tspan dy="5em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">THE ARCHITECT IN ADVANCE.</tspan>
|
||
<tspan dy="6em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● GENERAL CONTRACTOR RESPONSIBLE FOR ALL FEES ASSOCIATED WITH PERMITS, APPLICATIONS, TAXES,</tspan>
|
||
<tspan dy="7em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">AND CERTIFICATES OF INSPECTIONS.</tspan>
|
||
<tspan dy="8em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● ANY CONSTRUCTION THAT DEVIATES FROM THE DRAWING IS UNAUTHORIZED, IF NOT AUTHORIZED BY THE</tspan>
|
||
<tspan dy="9em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">ARCHITECT. IN SUCH AN EVENT, CONTRACTOR IS RESPONSIBLE FOR ANY REWORK THAT MIGHT BE REQUIRED.</tspan>
|
||
<tspan dy="10em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● CONTRACTOR IS RESPONSIBLE FOR ALL THE RULES/REGULATIONS OF THE AUTHORITY HAVING</tspan>
|
||
<tspan dy="11em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">JURISDICTION. INCLUDED, BUT NOT LIMITED TO ALL CITY, TOWNSHIP, COUNTY, STATE, AND FEDERAL</tspan>
|
||
<tspan dy="12em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">CODES, STATUTES, AND ORDINANCES.</tspan>
|
||
<tspan dy="13em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● CONTRACTORS SHALL VISIT THE SITE PRIOR TO CONSTRUCTION TO DETERMINE HOW NEW CONSTRUCTION IS</tspan>
|
||
<tspan dy="14em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">COMPATIBLE WITH EXISTING CONDITIONS.</tspan>
|
||
<tspan dy="15em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● CONTRACTOR TO NOTIFY ARCHITECT IF THERE ARE ANY OMISSIONS, CONFLICTS, OR DISCREPANCIES IN</tspan>
|
||
<tspan dy="16em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">THE DRAWINGS BEFORE ANY CONSTRUCTION TAKES PLACE. A FAILURE TO SO WILL RESULT IN THE</tspan>
|
||
<tspan dy="17em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">CONTRACTOR RESPONSIBLE FOR ANY REWORK.</tspan>
|
||
<tspan dy="18em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● CONTRACTOR RESPONSIBLE FOR VERIFYING ALL DIMENSIONS AND TAKEOFFS BEFORE BIDDING AND/OR</tspan>
|
||
<tspan dy="19em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">ORDERING MATERIALS. CONTRACTOR WILL NOTIFY ARCHITECT IF THERE ANY DRAWING CONFLICTS AND AWAIT</tspan>
|
||
<tspan dy="20em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">DIRECTION BEFORE COMMENCING.</tspan>
|
||
<tspan dy="21em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● DO NOT SCALE THE DRAWINGS.</tspan>
|
||
<tspan dy="22em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● ALL THROUGH AND MEMBRANE PENETRATIONS AT ALL FIRE/SMOKE RATED PARTITIONS/CEILINGS/FLOORS TO</tspan>
|
||
<tspan dy="23em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">BE SEALED WITH A CODE COMPLIANT, U.L. APPROVED FIRE STOP.</tspan>
|
||
<tspan dy="24em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● GENERAL CONTRACTOR TO COORDINATE THE SIZE/LOCATION OF ANY ACCESS PANELS AND/OR CLEAN OUTS</tspan>
|
||
<tspan dy="25em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">WITH THE M/E/P CONTRACTOR AND ARCHITECT.</tspan>
|
||
<tspan dy="26em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● ALL CONTRACTORS AND VENDORS TO FAMILIARIZE THEMSELVES WITH THE ENTIRE DRAWING SET, AS</tspan>
|
||
<tspan dy="27em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">REQUIRED INFORMATION MAY BE ON MULTIPLE SHEETS AND ALTERNATE DISCIPLINES.</tspan>
|
||
<tspan dy="28em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● ANY FURNITURE SHOWN IS FOR REFERENCE ONLY.</tspan>
|
||
<tspan dy="29em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● CONTRACTORS SHALL BE RESPONSIBLE FOR REPAIRING ANY PROPERTY DAMAGE THAT MAY HAVE RESULTED</tspan>
|
||
<tspan dy="30em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">FROM THEIR WORK.</tspan>
|
||
<tspan dy="31em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● OWNER RESPONSIBLE FOR ANY WORK NOT SPECIFICALLY CALLED OUT IN THE DRAWINGS.</tspan>
|
||
<tspan dy="32em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● ANY CHANGE THAT RESULTS IN ADDITIONAL COST/TIME MUST TO APPROVED BY THE OWNER/ARCHITECT</tspan>
|
||
<tspan dy="33em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">PRIOR TO CONSTRUCTION.</tspan>
|
||
<tspan dy="34em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● DETAILS ARE TO BE INTERPRETED AS TYPICAL. THAT IS, UNLESS SPECIFICALLY CALLED OUT OTHERWISE,</tspan>
|
||
<tspan dy="35em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">THE DETAIL IS TO BE APPLIED TO SIMILAR CONDITIONS THROUGHOUT THE PROJECT.</tspan>
|
||
<tspan dy="36em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● ALL EXTERIOR FLATWORK AROUND THE BUILDING TO SLOPE A MINIMUM OF 2% AWAY FROM THE BUILDING.</tspan>
|
||
<tspan dy="37em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● ANY PENETRATIONS IN THE EXTERIOR ENVELOPE TO BE SEALED TO PREVENT ANY AIR/WATER LEAKAGE PER</tspan>
|
||
<tspan dy="38em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">IBC CODE REQUIREMENTS.</tspan>
|
||
<tspan dy="39em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● ON THE DRAWINGS, NOTIFY ARCHITECT OF ANY PENETRATIONS IN THE EXTERIOR WALL THAT ARE LARGER</tspan>
|
||
<tspan dy="40em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">THAN 12"X12"</tspan>
|
||
<tspan dy="41em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● UNLESS OTHERWISE NOTED, SLOPE FLOOR 2% TOWARD ANY DRAINS INDICATED ON THE DRAWINGS.</tspan>
|
||
<tspan dy="42em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● CONTRACTOR SHALL KEEP THE CONSTRUCTION CLEAN–REMOVING ANY ACCUMULATION OF DEBRIS AND/OR</tspan>
|
||
<tspan dy="43em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">UNUSED EQUIPMENT.</tspan>
|
||
<tspan dy="44em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● CONTRACTOR TO BE RESPONSIBLE FOR THE COLLECTION, TRANSPORT AND DISPOSAL OF ALL CONSTRUCTION</tspan>
|
||
<tspan dy="45em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">WASTE.</tspan>
|
||
<tspan dy="46em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● CONTRACTORS RESPONSIBLE FOR ANY TEMPORARY SHORING THAT MIGHT BE NECESSARY DURING</tspan>
|
||
<tspan dy="47em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">CONSTRUCTION. ALL SHORING TO BE DESIGNED BY A LICENSED STRUCTURAL ENGINEER RETAINED BY THE</tspan>
|
||
<tspan dy="48em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">CONTRACTOR.</tspan>
|
||
<tspan dy="49em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● GENERAL CONTRACTOR TO VERIFY WITH THE M/E/P CONTRACTORS ALL PIPE/DUCT LOCATION PRIOR TO</tspan>
|
||
<tspan dy="50em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">FRAMING.</tspan>
|
||
<tspan dy="51em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● MANUFACTURED MATERIAL/EQUIPMENT TO BE INSTALLED PER MANUFACTURER’S REQUIREMENTS.</tspan>
|
||
<tspan dy="52em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● CONTRACTOR TO PROTECT ANY EXPOSED CONCRETE THAT IS MEANT TO BE A FINISHED SURFACE.</tspan>
|
||
<tspan dy="53em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● GENERAL CONTRACTOR TO PROVIDE ARCHITECT AT LEAST (2) WEEKS WHEN REVIEWING ANY SHOP DRAWINGS</tspan>
|
||
<tspan dy="54em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">AND/OR SUBSTITUTION REQUESTS.</tspan>
|
||
<tspan dy="55em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● REVIEW OF SHOP DRAWINGS DOES NOT CONSTITUTE THE APPROVAL OF SAFETY REQUIREMENTS AND/OR</tspan>
|
||
<tspan dy="56em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">CONSTRUCTION MEAN AND METHODS.</tspan>
|
||
<tspan dy="57em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● THE PRESENCE OF THE ARCHITECT ON SITE DOES NOT CONSTITUTE APPROVAL OF THE WORK. THE</tspan>
|
||
<tspan dy="58em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">CONTRACTOR SHALL CALL THE ARCHITECT’S ATTENTION TO ANYTHING SPECIFICALLY NEEDS THE ARCHITECT’S</tspan>
|
||
<tspan dy="59em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">APPROVAL.</tspan>
|
||
<tspan dy="60em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● ONLY ARCHITECTURAL AND STRUCTURAL DRAWINGS HAVE BEEN COORDINATED WITH THE ARCHITECT.</tspan>
|
||
<tspan dy="61em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">CONTRACTOR SHALL NOTIFY ARCHITECT OF ANY WORK OUTSIDE THESE SCOPES (M/E/P, FOR EXAMPLE) THAT</tspan>
|
||
<tspan dy="62em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">INTERFERES WITH THIS ARCH/STRUCT DRAWING SET.</tspan>
|
||
<tspan dy="63em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● GENERAL CONTRACTOR TO EDUCATE THE OWNER ON THE OPERATION AND MAINTENANCE OF ALL INSTALLED</tspan>
|
||
<tspan dy="64em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">PRODUCT AND/OR EQUIPMENT.</tspan>
|
||
<tspan dy="65em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● PRIOR TO SUBSTANTIAL COMPLETION, THE CONTRACTOR SHALL CLEAN SITE AND DELIVER ALL REQUIRED</tspan>
|
||
<tspan dy="66em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">GUARANTEES, LIEN WAITERS AND MAINTENANCE MANUALS</tspan>
|
||
<tspan dy="67em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● ARCHITECT NOT RESPONSIBLE FOR THE EXPLORATION, PRESENCE, HANDLING, AND/OR ADVERSE EXPOSURE</tspan>
|
||
<tspan dy="68em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">OF ANY HAZARDOUS MATERIALS, IN ANY FROM. INCLUDING, BUT NOT LIMITED TO ASBESTOS PRODUCTS,</tspan>
|
||
<tspan dy="69em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">POLYCHLORINATED BIPHENYL (PCB) OR OTHER TOXIC SUBSTANCES.</tspan>
|
||
<tspan dy="70em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● ALL EXTERIOR STRUCTURAL STEEL SHALL BE HOT DIPPED GALVANIZED. ALL NOTCHING, DRILLING,</tspan>
|
||
<tspan dy="71em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">WELDING AND BENDING DONE PRIOR TO DIPPING.</tspan>
|
||
<tspan dy="72em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● ANY PRODUCT OR MATERIALS THAT ARE NOT CALLED OUT IN THE DRAWINGS, BUT REQUIRED FOR PROPER</tspan>
|
||
<tspan dy="73em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">INSTALLATION AND PERFORMANCE OF THE WORK, SHALL BE PROVIDED BY THE CONTRACTOR.</tspan>
|
||
<tspan dy="74em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● THE CONTRACTOR TO PROVIDE ALL THE NECESSARY BLOCKING AND/OR STRUCTURAL SUPPORT REQUIRE TO</tspan>
|
||
<tspan dy="75em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">PROPERLY INSTALL MOUNTED ASSEMBLIES, INCLUDED BY NOT LIMITED TO GRAB BARS, PLUMBING FIXTURES,</tspan>
|
||
<tspan dy="76em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">MILLWORK AND CASEWORK.</tspan>
|
||
<tspan dy="77em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● MAINTAIN INGRESS AND EGRESS TO THE PROJECT SITE DURING CONSTRUCTION</tspan>
|
||
<tspan dy="78em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● ALL LUMBER ASSUMED TO BE SYP NO. 2 OR GREATER</tspan>
|
||
<tspan dy="79em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● ANY NEW OR MODIFIED FIRE ALARMS TO INTEGRATE WITH EXISTING FIRE ALARM ON THE PREMISES.</tspan>
|
||
<tspan dy="80em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● BEFORE CORING ANY PRETENSION OR POST-TENSION CONCRETE SLABS, GC TO RETAIN 3RD PARTY SCANNING</tspan>
|
||
<tspan dy="81em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">COMPANY AND HAVE REPORT REVIEWED AND APPROVED BY THE BUILDING OWNER'S STRUCTURAL ENGINEER.</tspan>
|
||
</text>
|
||