Restaurant_MPM/Open/Models/BlenderBIM/schedules/GENERAL NOTES.svg

153 lines
16 KiB
XML
Raw Permalink Blame History

This file contains ambiguous Unicode characters

This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.

<?xml version="1.0" encoding="utf-8" ?>
<svg xmlns="http://www.w3.org/2000/svg" xmlns:ev="http://www.w3.org/2001/xml-events" xmlns:xlink="http://www.w3.org/1999/xlink" baseProfile="full" height="285.80943999999994mm" id="root" version="1.1" viewBox="0 0 201.90053999999998 285.80943999999994" width="201.90053999999998mm">
<defs>
<style type="text/css"><![CDATA[/*
* BlenderBIM Add-on - OpenBIM Blender Add-on
* Copyright (C) 2020, 2021 Dion Moult <dion@thinkmoult.com>
*
* This file is part of BlenderBIM Add-on.
*
* BlenderBIM Add-on is free software: you can redistribute it and/or modify
* it under the terms of the GNU General Public License as published by
* the Free Software Foundation, either version 3 of the License, or
* (at your option) any later version.
*
* BlenderBIM Add-on is distributed in the hope that it will be useful,
* but WITHOUT ANY WARRANTY, without even the implied warranty of
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
* GNU General Public License for more details.
*
* You should have received a copy of the GNU General Public License
* along with BlenderBIM Add-on. If not, see <http://www.gnu.org/licenses/>.
*/
/**
* You may copy this `schedule.css` template alongside your input schedule
* document with the same filename. For example if you have a schedule called
* `door_types.ods`, you can create a `door_types.css` in the same folder to
* style that schedule.
*/
/**
* If you specify a font size in CSS, such as text { font-size: 5; }, all fonts
* will be overriden to match that size.
*
* If your CSS, ODS, XLSX does not specify a font size, the variables below
* will specify the default font size.
*
* If your ODS, XLSX does specify a font size, they will scale linearly based
* on the variables below.
*/
:root {
--font-size-pt: 10.9;
--font-size-px: 3.65;
--font-width: 0.63;
}
text,
tspan {
/* 2.5mm */
fill: #2c5573 !important;
stroke: none !important;
font-family: "Century Gothic", "OpenGost Type B TT", "DejaVu Sans Condensed",
"Liberation Sans", "Arial Narrow", "Arial" !important;
}
.border {
stroke: #2c5573;
stroke-width: 0.3;
fill: none;
}
]]></style>
</defs>
<rect class="border" height="6.670039999999999" style="fill: #ffffff;" width="199.90053999999998" x="1" y="1"/>
<text dominant-baseline="hanging" fill="#406183" font-size="0" text-anchor="start">
<tspan dy="0em" fill="#406183" font-size="3.348623853211009" x="2" y="2">GENERAL NOTES</tspan>
</text>
<rect class="border" height="277.13939999999997" style="fill: #ffffff;" width="199.90053999999998" x="1" y="7.670039999999999"/>
<text dominant-baseline="hanging" fill="#406183" font-size="0" text-anchor="start">
<tspan dy="0em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● THE MECHANICAL (HVAC), ELECTRICAL, PLUMBING, FIRE PROTECTION, AND FIRE ALARM SYSTEMS WILL BE</tspan>
<tspan dy="1em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">DESIGNED AND CONSTRUCTED USING THE DESIGN-BUILD DELIVERY METHOD. THESE SPECIFIC DETAILS ARE</tspan>
<tspan dy="2em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">NOT PROVIDED IN THESE DOCUMENTS. IT IS THE RESPONSIBILITY OF THE M/E/P/FP/A CONTRACTOR TO</tspan>
<tspan dy="3em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">COORDINATE WITH THE GENERAL CONTRACTOR AND UTILIZE THESE DRAWINGS TO GUIDE THE FINAL DESIGN OF</tspan>
<tspan dy="4em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">THEIR SYSTEMS. ANY CHANGES TO THE STRUCTURE OR ARCHITECTURAL FEATURES MUST BE COMMUNICATED TO</tspan>
<tspan dy="5em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">THE ARCHITECT IN ADVANCE.</tspan>
<tspan dy="6em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● GENERAL CONTRACTOR RESPONSIBLE FOR ALL FEES ASSOCIATED WITH PERMITS, APPLICATIONS, TAXES,</tspan>
<tspan dy="7em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">AND CERTIFICATES OF INSPECTIONS.</tspan>
<tspan dy="8em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● ANY CONSTRUCTION THAT DEVIATES FROM THE DRAWING IS UNAUTHORIZED, IF NOT AUTHORIZED BY THE</tspan>
<tspan dy="9em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">ARCHITECT. IN SUCH AN EVENT, CONTRACTOR IS RESPONSIBLE FOR ANY REWORK THAT MIGHT BE REQUIRED.</tspan>
<tspan dy="10em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● CONTRACTOR IS RESPONSIBLE FOR ALL THE RULES/REGULATIONS OF THE AUTHORITY HAVING</tspan>
<tspan dy="11em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">JURISDICTION. INCLUDED, BUT NOT LIMITED TO ALL CITY, TOWNSHIP, COUNTY, STATE, AND FEDERAL</tspan>
<tspan dy="12em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">CODES, STATUTES, AND ORDINANCES.</tspan>
<tspan dy="13em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● CONTRACTORS SHALL VISIT THE SITE PRIOR TO CONSTRUCTION TO DETERMINE HOW NEW CONSTRUCTION IS</tspan>
<tspan dy="14em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">COMPATIBLE WITH EXISTING CONDITIONS.</tspan>
<tspan dy="15em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● CONTRACTOR TO NOTIFY ARCHITECT IF THERE ARE ANY OMISSIONS, CONFLICTS, OR DISCREPANCIES IN</tspan>
<tspan dy="16em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">THE DRAWINGS BEFORE ANY CONSTRUCTION TAKES PLACE. A FAILURE TO SO WILL RESULT IN THE</tspan>
<tspan dy="17em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">CONTRACTOR RESPONSIBLE FOR ANY REWORK.</tspan>
<tspan dy="18em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● CONTRACTOR RESPONSIBLE FOR VERIFYING ALL DIMENSIONS AND TAKEOFFS BEFORE BIDDING AND/OR</tspan>
<tspan dy="19em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">ORDERING MATERIALS. CONTRACTOR WILL NOTIFY ARCHITECT IF THERE ANY DRAWING CONFLICTS AND AWAIT</tspan>
<tspan dy="20em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">DIRECTION BEFORE COMMENCING.</tspan>
<tspan dy="21em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● DO NOT SCALE THE DRAWINGS.</tspan>
<tspan dy="22em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● ALL THROUGH AND MEMBRANE PENETRATIONS AT ALL FIRE/SMOKE RATED PARTITIONS/CEILINGS/FLOORS TO</tspan>
<tspan dy="23em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">BE SEALED WITH A CODE COMPLIANT, U.L. APPROVED FIRE STOP.</tspan>
<tspan dy="24em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● GENERAL CONTRACTOR TO COORDINATE THE SIZE/LOCATION OF ANY ACCESS PANELS AND/OR CLEAN OUTS</tspan>
<tspan dy="25em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">WITH THE M/E/P CONTRACTOR AND ARCHITECT.</tspan>
<tspan dy="26em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● ALL CONTRACTORS AND VENDORS TO FAMILIARIZE THEMSELVES WITH THE ENTIRE DRAWING SET, AS</tspan>
<tspan dy="27em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">REQUIRED INFORMATION MAY BE ON MULTIPLE SHEETS AND ALTERNATE DISCIPLINES.</tspan>
<tspan dy="28em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● ANY FURNITURE SHOWN IS FOR REFERENCE ONLY.</tspan>
<tspan dy="29em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● CONTRACTORS SHALL BE RESPONSIBLE FOR REPAIRING ANY PROPERTY DAMAGE THAT MAY HAVE RESULTED</tspan>
<tspan dy="30em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">FROM THEIR WORK.</tspan>
<tspan dy="31em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● OWNER RESPONSIBLE FOR ANY WORK NOT SPECIFICALLY CALLED OUT IN THE DRAWINGS.</tspan>
<tspan dy="32em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● ANY CHANGE THAT RESULTS IN ADDITIONAL COST/TIME MUST TO APPROVED BY THE OWNER/ARCHITECT</tspan>
<tspan dy="33em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">PRIOR TO CONSTRUCTION.</tspan>
<tspan dy="34em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● DETAILS ARE TO BE INTERPRETED AS TYPICAL. THAT IS, UNLESS SPECIFICALLY CALLED OUT OTHERWISE,</tspan>
<tspan dy="35em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">THE DETAIL IS TO BE APPLIED TO SIMILAR CONDITIONS THROUGHOUT THE PROJECT.</tspan>
<tspan dy="36em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● ALL EXTERIOR FLATWORK AROUND THE BUILDING TO SLOPE A MINIMUM OF 2% AWAY FROM THE BUILDING.</tspan>
<tspan dy="37em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● ANY PENETRATIONS IN THE EXTERIOR ENVELOPE TO BE SEALED TO PREVENT ANY AIR/WATER LEAKAGE PER</tspan>
<tspan dy="38em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">IBC CODE REQUIREMENTS.</tspan>
<tspan dy="39em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● ON THE DRAWINGS, NOTIFY ARCHITECT OF ANY PENETRATIONS IN THE EXTERIOR WALL THAT ARE LARGER</tspan>
<tspan dy="40em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">THAN 12&quot;X12&quot;</tspan>
<tspan dy="41em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● UNLESS OTHERWISE NOTED, SLOPE FLOOR 2% TOWARD ANY DRAINS INDICATED ON THE DRAWINGS.</tspan>
<tspan dy="42em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● CONTRACTOR SHALL KEEP THE CONSTRUCTION CLEANREMOVING ANY ACCUMULATION OF DEBRIS AND/OR</tspan>
<tspan dy="43em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">UNUSED EQUIPMENT.</tspan>
<tspan dy="44em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● CONTRACTOR TO BE RESPONSIBLE FOR THE COLLECTION, TRANSPORT AND DISPOSAL OF ALL CONSTRUCTION</tspan>
<tspan dy="45em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">WASTE.</tspan>
<tspan dy="46em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● CONTRACTORS RESPONSIBLE FOR ANY TEMPORARY SHORING THAT MIGHT BE NECESSARY DURING</tspan>
<tspan dy="47em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">CONSTRUCTION. ALL SHORING TO BE DESIGNED BY A LICENSED STRUCTURAL ENGINEER RETAINED BY THE</tspan>
<tspan dy="48em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">CONTRACTOR.</tspan>
<tspan dy="49em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● GENERAL CONTRACTOR TO VERIFY WITH THE M/E/P CONTRACTORS ALL PIPE/DUCT LOCATION PRIOR TO</tspan>
<tspan dy="50em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">FRAMING.</tspan>
<tspan dy="51em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● MANUFACTURED MATERIAL/EQUIPMENT TO BE INSTALLED PER MANUFACTURERS REQUIREMENTS.</tspan>
<tspan dy="52em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● CONTRACTOR TO PROTECT ANY EXPOSED CONCRETE THAT IS MEANT TO BE A FINISHED SURFACE.</tspan>
<tspan dy="53em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● GENERAL CONTRACTOR TO PROVIDE ARCHITECT AT LEAST (2) WEEKS WHEN REVIEWING ANY SHOP DRAWINGS</tspan>
<tspan dy="54em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">AND/OR SUBSTITUTION REQUESTS.</tspan>
<tspan dy="55em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● REVIEW OF SHOP DRAWINGS DOES NOT CONSTITUTE THE APPROVAL OF SAFETY REQUIREMENTS AND/OR</tspan>
<tspan dy="56em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">CONSTRUCTION MEAN AND METHODS.</tspan>
<tspan dy="57em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● THE PRESENCE OF THE ARCHITECT ON SITE DOES NOT CONSTITUTE APPROVAL OF THE WORK. THE</tspan>
<tspan dy="58em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">CONTRACTOR SHALL CALL THE ARCHITECTS ATTENTION TO ANYTHING SPECIFICALLY NEEDS THE ARCHITECTS</tspan>
<tspan dy="59em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">APPROVAL.</tspan>
<tspan dy="60em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● ONLY ARCHITECTURAL AND STRUCTURAL DRAWINGS HAVE BEEN COORDINATED WITH THE ARCHITECT.</tspan>
<tspan dy="61em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">CONTRACTOR SHALL NOTIFY ARCHITECT OF ANY WORK OUTSIDE THESE SCOPES (M/E/P, FOR EXAMPLE) THAT</tspan>
<tspan dy="62em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">INTERFERES WITH THIS ARCH/STRUCT DRAWING SET.</tspan>
<tspan dy="63em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● GENERAL CONTRACTOR TO EDUCATE THE OWNER ON THE OPERATION AND MAINTENANCE OF ALL INSTALLED</tspan>
<tspan dy="64em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">PRODUCT AND/OR EQUIPMENT.</tspan>
<tspan dy="65em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● PRIOR TO SUBSTANTIAL COMPLETION, THE CONTRACTOR SHALL CLEAN SITE AND DELIVER ALL REQUIRED</tspan>
<tspan dy="66em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">GUARANTEES, LIEN WAITERS AND MAINTENANCE MANUALS</tspan>
<tspan dy="67em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● ARCHITECT NOT RESPONSIBLE FOR THE EXPLORATION, PRESENCE, HANDLING, AND/OR ADVERSE EXPOSURE</tspan>
<tspan dy="68em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">OF ANY HAZARDOUS MATERIALS, IN ANY FROM. INCLUDING, BUT NOT LIMITED TO ASBESTOS PRODUCTS,</tspan>
<tspan dy="69em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">POLYCHLORINATED BIPHENYL (PCB) OR OTHER TOXIC SUBSTANCES.</tspan>
<tspan dy="70em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● ALL EXTERIOR STRUCTURAL STEEL SHALL BE HOT DIPPED GALVANIZED. ALL NOTCHING, DRILLING,</tspan>
<tspan dy="71em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">WELDING AND BENDING DONE PRIOR TO DIPPING.</tspan>
<tspan dy="72em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● ANY PRODUCT OR MATERIALS THAT ARE NOT CALLED OUT IN THE DRAWINGS, BUT REQUIRED FOR PROPER</tspan>
<tspan dy="73em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">INSTALLATION AND PERFORMANCE OF THE WORK, SHALL BE PROVIDED BY THE CONTRACTOR.</tspan>
<tspan dy="74em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● THE CONTRACTOR TO PROVIDE ALL THE NECESSARY BLOCKING AND/OR STRUCTURAL SUPPORT REQUIRE TO</tspan>
<tspan dy="75em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">PROPERLY INSTALL MOUNTED ASSEMBLIES, INCLUDED BY NOT LIMITED TO GRAB BARS, PLUMBING FIXTURES,</tspan>
<tspan dy="76em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">MILLWORK AND CASEWORK.</tspan>
<tspan dy="77em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● MAINTAIN INGRESS AND EGRESS TO THE PROJECT SITE DURING CONSTRUCTION</tspan>
<tspan dy="78em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● ALL LUMBER ASSUMED TO BE SYP NO. 2 OR GREATER</tspan>
<tspan dy="79em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● ANY NEW OR MODIFIED FIRE ALARMS TO INTEGRATE WITH EXISTING FIRE ALARM ON THE PREMISES.</tspan>
<tspan dy="80em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">● BEFORE CORING ANY PRETENSION OR POST-TENSION CONCRETE SLABS, GC TO RETAIN 3RD PARTY SCANNING</tspan>
<tspan dy="81em" fill="#406183" font-size="3.348623853211009" x="2" y="8.67004">COMPANY AND HAVE REPORT REVIEWED AND APPROVED BY THE BUILDING OWNER'S STRUCTURAL ENGINEER.</tspan>
</text>