37 lines
5.5 KiB
XML
37 lines
5.5 KiB
XML
<?xml version="1.0" encoding="utf-8" ?>
|
|
<svg xmlns="http://www.w3.org/2000/svg" xmlns:ev="http://www.w3.org/2001/xml-events" xmlns:xlink="http://www.w3.org/1999/xlink" baseProfile="full" height="102.49mm" id="root" version="1.1" viewBox="0 0 118.89 102.49" width="118.89mm">
|
|
<defs/>
|
|
<rect height="6.67" style="fill: #ffffff; stroke-width:.125; stroke: #000000;" width="116.89" x="1" y="1"/>
|
|
<text dominant-baseline="baseline" fill="#406183" font-family="OpenGost Type B TT" font-size="0" text-anchor="start">
|
|
<tspan dy="0em" fill="#406183" font-family="OpenGost Type B TT" font-size="3.441666666666667" x="2" y="6.67">DEMOLITION NOTES</tspan>
|
|
</text>
|
|
<rect height="93.82" style="fill: #ffffff; stroke-width:.125; stroke: #000000;" width="116.89" x="1" y="7.67"/>
|
|
<text dominant-baseline="baseline" fill="#406183" font-family="OpenGost Type B TT" font-size="0" text-anchor="start">
|
|
<tspan dy="0em" fill="#406183" font-family="OpenGost Type B TT" font-size="3.441666666666667" x="2" y="100.49">ADDITIONAL DEMOLITION SCOPE</tspan>
|
|
<tspan dy="-1em" fill="#406183" font-family="OpenGost Type B TT" font-size="3.441666666666667" x="2" y="100.49">● SEE MECHANICAL/ELECTRICAL/PLUMBING/FIRE PROTECTION DRAWINGS FOR ANY</tspan>
|
|
<tspan dy="-2em" fill="#406183" font-family="OpenGost Type B TT" font-size="3.441666666666667" x="2" y="100.49">CONTRACTOR</tspan>
|
|
<tspan dy="-3em" fill="#406183" font-family="OpenGost Type B TT" font-size="3.441666666666667" x="2" y="100.49">SHORING TO BE DESIGNED BY A LICENSED STRUCTURAL ENGINEER RETAINED BY THE</tspan>
|
|
<tspan dy="-4em" fill="#406183" font-family="OpenGost Type B TT" font-size="3.441666666666667" x="2" y="100.49">STRUCTURAL MEMBERS ARE REMOVED TO ACCOMMODATE ANY NEW CONSTRUCTION. ALL</tspan>
|
|
<tspan dy="-5em" fill="#406183" font-family="OpenGost Type B TT" font-size="3.441666666666667" x="2" y="100.49">● CONTRACTOR RESPONSIBLE FOR ANY TEMPORARY SHORING NECESSARY WHEN EXISTING</tspan>
|
|
<tspan dy="-6em" fill="#406183" font-family="OpenGost Type B TT" font-size="3.441666666666667" x="2" y="100.49">LOCAL/STATE/FEDERAL LAWS</tspan>
|
|
<tspan dy="-7em" fill="#406183" font-family="OpenGost Type B TT" font-size="3.441666666666667" x="2" y="100.49">HAZARDOUS MATERIALS AND IF SO, ARE LEGALLY REMOVED IN COMPLIANCE WITH</tspan>
|
|
<tspan dy="-8em" fill="#406183" font-family="OpenGost Type B TT" font-size="3.441666666666667" x="2" y="100.49">● OWNER/GC/SUBS ARE RESPONSIBLE TO TEST IF REMOVED ITEMS CONTAIN ANY</tspan>
|
|
<tspan dy="-9em" fill="#406183" font-family="OpenGost Type B TT" font-size="3.441666666666667" x="2" y="100.49">ACCOMMODATE THE PLANNED CONSTRUCTION SCOPE.</tspan>
|
|
<tspan dy="-10em" fill="#406183" font-family="OpenGost Type B TT" font-size="3.441666666666667" x="2" y="100.49">● ADDITIONAL DEMOLITION, BEYOND WHAT IS IDENTIFIED HERE, MAY BE REQUIRED TO</tspan>
|
|
<tspan dy="-11em" fill="#406183" font-family="OpenGost Type B TT" font-size="3.441666666666667" x="2" y="100.49">NECESSARY OUTSIDE TENANT SPACE</tspan>
|
|
<tspan dy="-12em" fill="#406183" font-family="OpenGost Type B TT" font-size="3.441666666666667" x="2" y="100.49">● CONTRACTOR TO NOTIFY OWNER AND/OR LANDLORD OF ANY DEMOLITION THAT IS</tspan>
|
|
<tspan dy="-13em" fill="#406183" font-family="OpenGost Type B TT" font-size="3.441666666666667" x="2" y="100.49">CHISELING) TO RECEIVE ANY SCHEDULE FINISHED</tspan>
|
|
<tspan dy="-14em" fill="#406183" font-family="OpenGost Type B TT" font-size="3.441666666666667" x="2" y="100.49">● ALL FLOORS TO BE LEVELED AS NECESSARY (GRINDING, PATCHING, LEVELING,</tspan>
|
|
<tspan dy="-15em" fill="#406183" font-family="OpenGost Type B TT" font-size="3.441666666666667" x="2" y="100.49">SCOPE</tspan>
|
|
<tspan dy="-16em" fill="#406183" font-family="OpenGost Type B TT" font-size="3.441666666666667" x="2" y="100.49">ASSOCIATED FEES) OF ANY SERVICE UTILITIES ASSOCIATED WITH THE DEMOLITION</tspan>
|
|
<tspan dy="-17em" fill="#406183" font-family="OpenGost Type B TT" font-size="3.441666666666667" x="2" y="100.49">● CONTRACTOR TO COORDINATE THE DISCONNECTION AND CAPPING (AND ANY</tspan>
|
|
<tspan dy="-18em" fill="#406183" font-family="OpenGost Type B TT" font-size="3.441666666666667" x="2" y="100.49">THAT ARE OUTSIDE THE DEMOLITION SCOPE.</tspan>
|
|
<tspan dy="-19em" fill="#406183" font-family="OpenGost Type B TT" font-size="3.441666666666667" x="2" y="100.49">● SEAL THE INTAKE/EXHAUST OF ANY DUCTS THAT ROUTE INTO ADJOINING SPACES</tspan>
|
|
<tspan dy="-20em" fill="#406183" font-family="OpenGost Type B TT" font-size="3.441666666666667" x="2" y="100.49">DUST/FUMES AND PATCHED/REPAIRED AS NECESSARY</tspan>
|
|
<tspan dy="-21em" fill="#406183" font-family="OpenGost Type B TT" font-size="3.441666666666667" x="2" y="100.49">● CONTRACTOR TO PROTECT ALL EXISTING CONSTRUCTION FROM DAMAGE AND</tspan>
|
|
<tspan dy="-22em" fill="#406183" font-family="OpenGost Type B TT" font-size="3.441666666666667" x="2" y="100.49">IF THERE IS ANY QUESTION.</tspan>
|
|
<tspan dy="-23em" fill="#406183" font-family="OpenGost Type B TT" font-size="3.441666666666667" x="2" y="100.49">THEY ARE NOT LOAD BEARING, AND CAN BE REMOVED. CONSULT WITH THE ARCHITECT</tspan>
|
|
<tspan dy="-24em" fill="#406183" font-family="OpenGost Type B TT" font-size="3.441666666666667" x="2" y="100.49">PLAN, TO BE LOAD BEARING. CONTRACTOR RESPONSIBLE TO MAKE THE DETERMINATION</tspan>
|
|
<tspan dy="-25em" fill="#406183" font-family="OpenGost Type B TT" font-size="3.441666666666667" x="2" y="100.49">● CONTRACTOR TO ASSUME ALL WALLS/COLUMNS INDICATED TO BE DEMOLISHED ON THE</tspan>
|
|
</text>
|
|
</svg>
|