<svg xmlns="http://www.w3.org/2000/svg" xmlns:ev="http://www.w3.org/2001/xml-events" xmlns:xlink="http://www.w3.org/1999/xlink" baseProfile="full" height="218.61119999999997mm" id="root" version="1.1" viewBox="0 0 197.74002 218.61119999999997" width="197.74002mm">
<defs>
<style type="text/css"><![CDATA[/*
* BlenderBIM Add-on - OpenBIM Blender Add-on
* Copyright (C) 2020, 2021 Dion Moult <dion@thinkmoult.com>
*
* This file is part of BlenderBIM Add-on.
*
* BlenderBIM Add-on is free software: you can redistribute it and/or modify
* it under the terms of the GNU General Public License as published by
* the Free Software Foundation, either version 3 of the License, or
* (at your option) any later version.
*
* BlenderBIM Add-on is distributed in the hope that it will be useful,
* but WITHOUT ANY WARRANTY, without even the implied warranty of
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
* GNU General Public License for more details.
*
* You should have received a copy of the GNU General Public License
* along with BlenderBIM Add-on. If not, see <http://www.gnu.org/licenses/>.
*/
/**
* You may copy this `schedule.css` template alongside your input schedule
* document with the same filename. For example if you have a schedule called
* `door_types.ods`, you can create a `door_types.css` in the same folder to
* style that schedule.
*/
/**
* If you specify a font size in CSS, such as text { font-size: 5; }, all fonts
* will be overriden to match that size.
*
* If your CSS, ODS, XLSX does not specify a font size, the variables below
* will specify the default font size.
*
* If your ODS, XLSX does specify a font size, they will scale linearly based
* on the variables below.
*/
:root {
--font-size-pt: 12;
--font-size-px: 4.13;
--font-width: 0.45;
}
text, tspan { /* 2.5mm */ fill: black; stroke: none; font-family: 'OpenGost Type B TT', 'DejaVu Sans Condensed', 'Liberation Sans', 'Arial Narrow', 'Arial'; }
]]></style>
</defs>
<rect height="6.670039999999999" style="fill: #ffffff; stroke-width:.125; stroke: #000000;" width="195.74002" x="1" y="1"/>
<text dominant-baseline="hanging" fill="#406183" font-size="0" text-anchor="start">
<tspan dy="0em" fill="#406183" font-size="3.441666666666667" x="2" y="2">GENERAL NOTES</tspan>
</text>
<rect height="209.94115999999997" style="fill: #ffffff; stroke-width:.125; stroke: #000000;" width="195.74002" x="1" y="7.670039999999999"/>
<text dominant-baseline="hanging" fill="#406183" font-size="0" text-anchor="start">
<tspan dy="0em" fill="#406183" font-size="3.441666666666667" x="2" y="8.67004">● THE MECHANICAL (HVAC), ELECTRICAL, PLUMBING, FIRE PROTECTION, AND FIRE ALARM SYSTEMS WILL BE DESIGNED AND CONSTRUCTED USING</tspan>
<tspan dy="1em" fill="#406183" font-size="3.441666666666667" x="2" y="8.67004">THE DESIGN-BUILD DELIVERY METHOD. THESE SPECIFIC DETAILS ARE NOT PROVIDED IN THESE DOCUMENTS. IT IS THE RESPONSIBILITY OF THE</tspan>
<tspan dy="2em" fill="#406183" font-size="3.441666666666667" x="2" y="8.67004">M/E/P/FP/A CONTRACTOR TO COORDINATE WITH THE GENERAL CONTRACTOR AND UTILIZE THESE DRAWINGS TO GUIDE THE FINAL DESIGN OF THEIR</tspan>
<tspan dy="3em" fill="#406183" font-size="3.441666666666667" x="2" y="8.67004">SYSTEMS. ANY CHANGES TO THE STRUCTURE OR ARCHITECTURAL FEATURES MUST BE COMMUNICATED TO THE ARCHITECT IN ADVANCE.</tspan>
<tspan dy="4em" fill="#406183" font-size="3.441666666666667" x="2" y="8.67004">● GENERAL CONTRACTOR RESPONSIBLE FOR ALL FEES ASSOCIATED WITH PERMITS, APPLICATIONS, TAXES, AND CERTIFICATES OF INSPECTIONS.</tspan>
<tspan dy="5em" fill="#406183" font-size="3.441666666666667" x="2" y="8.67004">● ANY CONSTRUCTION THAT DEVIATES FROM THE DRAWING IS UNAUTHORIZED, IF NOT AUTHORIZED BY THE ARCHITECT. IN SUCH AN EVENT,</tspan>
<tspan dy="6em" fill="#406183" font-size="3.441666666666667" x="2" y="8.67004">CONTRACTOR IS RESPONSIBLE FOR ANY REWORK THAT MIGHT BE REQUIRED.</tspan>
<tspan dy="7em" fill="#406183" font-size="3.441666666666667" x="2" y="8.67004">● CONTRACTOR IS RESPONSIBLE FOR ALL THE RULES/REGULATIONS OF THE AUTHORITY HAVING JURISDICTION. INCLUDED, BUT NOT LIMITED TO</tspan>
<tspan dy="8em" fill="#406183" font-size="3.441666666666667" x="2" y="8.67004">ALL CITY, TOWNSHIP, COUNTY, STATE, AND FEDERAL CODES, STATUTES, AND ORDINANCES.</tspan>
<tspan dy="9em" fill="#406183" font-size="3.441666666666667" x="2" y="8.67004">● CONTRACTORS SHALL VISIT THE SITE PRIOR TO CONSTRUCTION TO DETERMINE HOW NEW CONSTRUCTION IS COMPATIBLE WITH EXISTING</tspan>
<tspan dy="10em" fill="#406183" font-size="3.441666666666667" x="2" y="8.67004">CONDITIONS.</tspan>
<tspan dy="11em" fill="#406183" font-size="3.441666666666667" x="2" y="8.67004">● CONTRACTOR TO NOTIFY ARCHITECT IF THERE ARE ANY OMISSIONS, CONFLICTS, OR DISCREPANCIES IN THE DRAWINGS BEFORE ANY</tspan>
<tspan dy="12em" fill="#406183" font-size="3.441666666666667" x="2" y="8.67004">CONSTRUCTION TAKES PLACE. A FAILURE TO SO WILL RESULT IN THE CONTRACTOR RESPONSIBLE FOR ANY REWORK.</tspan>
<tspan dy="13em" fill="#406183" font-size="3.441666666666667" x="2" y="8.67004">● CONTRACTOR RESPONSIBLE FOR VERIFYING ALL DIMENSIONS AND TAKEOFFS BEFORE BIDDING AND/OR ORDERING MATERIALS. CONTRACTOR WILL</tspan>
<tspan dy="14em" fill="#406183" font-size="3.441666666666667" x="2" y="8.67004">NOTIFY ARCHITECT IF THERE ANY DRAWING CONFLICTS AND AWAIT DIRECTION BEFORE COMMENCING.</tspan>
<tspan dy="15em" fill="#406183" font-size="3.441666666666667" x="2" y="8.67004">● DO NOT SCALE THE DRAWINGS.</tspan>
<tspan dy="16em" fill="#406183" font-size="3.441666666666667" x="2" y="8.67004">● ALL THROUGH AND MEMBRANE PENETRATIONS AT ALL FIRE/SMOKE RATED PARTITIONS/CEILINGS/FLOORS TO BE SEALED WITH A CODE COMPLIANT,</tspan>
<tspan dy="17em" fill="#406183" font-size="3.441666666666667" x="2" y="8.67004">U.L. APPROVED FIRE STOP.</tspan>
<tspan dy="18em" fill="#406183" font-size="3.441666666666667" x="2" y="8.67004">● GENERAL CONTRACTOR TO COORDINATE THE SIZE/LOCATION OF ANY ACCESS PANELS AND/OR CLEAN OUTS WITH THE M/E/P CONTRACTOR AND</tspan>
<tspan dy="19em" fill="#406183" font-size="3.441666666666667" x="2" y="8.67004">ARCHITECT.</tspan>
<tspan dy="20em" fill="#406183" font-size="3.441666666666667" x="2" y="8.67004">● ALL CONTRACTORS AND VENDORS TO FAMILIARIZE THEMSELVES WITH THE ENTIRE DRAWING SET, AS REQUIRED INFORMATION MAY BE ON</tspan>
<tspan dy="21em" fill="#406183" font-size="3.441666666666667" x="2" y="8.67004">MULTIPLE SHEETS AND ALTERNATE DISCIPLINES.</tspan>
<tspan dy="22em" fill="#406183" font-size="3.441666666666667" x="2" y="8.67004">● ANY FURNITURE SHOWN IS FOR REFERENCE ONLY.</tspan>
<tspan dy="23em" fill="#406183" font-size="3.441666666666667" x="2" y="8.67004">● CONTRACTORS SHALL BE RESPONSIBLE FOR REPAIRING ANY PROPERTY DAMAGE THAT MAY HAVE RESULTED FROM THEIR WORK.</tspan>
<tspan dy="24em" fill="#406183" font-size="3.441666666666667" x="2" y="8.67004">● OWNER RESPONSIBLE FOR ANY WORK NOT SPECIFICALLY CALLED OUT IN THE DRAWINGS.</tspan>
<tspan dy="25em" fill="#406183" font-size="3.441666666666667" x="2" y="8.67004">● ANY CHANGE THAT RESULTS IN ADDITIONAL COST/TIME MUST TO APPROVED BY THE OWNER/ARCHITECT PRIOR TO CONSTRUCTION.</tspan>
<tspan dy="26em" fill="#406183" font-size="3.441666666666667" x="2" y="8.67004">● DETAILS ARE TO BE INTERPRETED AS TYPICAL. THAT IS, UNLESS SPECIFICALLY CALLED OUT OTHERWISE, THE DETAIL IS TO BE APPLIED TO</tspan>
<tspan dy="27em" fill="#406183" font-size="3.441666666666667" x="2" y="8.67004">SIMILAR CONDITIONS THROUGHOUT THE PROJECT.</tspan>
<tspan dy="28em" fill="#406183" font-size="3.441666666666667" x="2" y="8.67004">● ALL EXTERIOR FLATWORK AROUND THE BUILDING TO SLOPE A MINIMUM OF 2% AWAY FROM THE BUILDING.</tspan>
<tspan dy="29em" fill="#406183" font-size="3.441666666666667" x="2" y="8.67004">● ANY PENETRATIONS IN THE EXTERIOR ENVELOPE TO BE SEALED TO PREVENT ANY AIR/WATER LEAKAGE PER IBC CODE REQUIREMENTS.</tspan>
<tspan dy="30em" fill="#406183" font-size="3.441666666666667" x="2" y="8.67004">● ON THE DRAWINGS, NOTIFY ARCHITECT OF ANY PENETRATIONS IN THE EXTERIOR WALL THAT ARE LARGER THAN 12&quot;X12&quot;</tspan>
<tspan dy="31em" fill="#406183" font-size="3.441666666666667" x="2" y="8.67004">● UNLESS OTHERWISE NOTED, SLOPE FLOOR 2% TOWARD ANY DRAINS INDICATED ON THE DRAWINGS.</tspan>
<tspan dy="32em" fill="#406183" font-size="3.441666666666667" x="2" y="8.67004">● CONTRACTOR SHALL KEEP THE CONSTRUCTION CLEANREMOVING ANY ACCUMULATION OF DEBRIS AND/OR UNUSED EQUIPMENT.</tspan>
<tspan dy="33em" fill="#406183" font-size="3.441666666666667" x="2" y="8.67004">● CONTRACTOR TO BE RESPONSIBLE FOR THE COLLECTION, TRANSPORT AND DISPOSAL OF ALL CONSTRUCTION WASTE.</tspan>
<tspan dy="34em" fill="#406183" font-size="3.441666666666667" x="2" y="8.67004">● CONTRACTORS RESPONSIBLE FOR ANY TEMPORARY SHORING THAT MIGHT BE NECESSARY DURING CONSTRUCTION. ALL SHORING TO BE DESIGNED BY</tspan>
<tspan dy="35em" fill="#406183" font-size="3.441666666666667" x="2" y="8.67004">A LICENSED STRUCTURAL ENGINEER RETAINED BY THE CONTRACTOR.</tspan>
<tspan dy="36em" fill="#406183" font-size="3.441666666666667" x="2" y="8.67004">● GENERAL CONTRACTOR TO VERIFY WITH THE M/E/P CONTRACTORS ALL PIPE/DUCT LOCATION PRIOR TO FRAMING.</tspan>
<tspan dy="37em" fill="#406183" font-size="3.441666666666667" x="2" y="8.67004">● MANUFACTURED MATERIAL/EQUIPMENT TO BE INSTALLED PER MANUFACTURERS REQUIREMENTS.</tspan>
<tspan dy="38em" fill="#406183" font-size="3.441666666666667" x="2" y="8.67004">● CONTRACTOR TO PROTECT ANY EXPOSED CONCRETE THAT IS MEANT TO BE A FINISHED SURFACE.</tspan>
<tspan dy="39em" fill="#406183" font-size="3.441666666666667" x="2" y="8.67004">● GENERAL CONTRACTOR TO PROVIDE ARCHITECT AT LEAST (2) WEEKS WHEN REVIEWING ANY SHOP DRAWINGS AND/OR SUBSTITUTION REQUESTS.</tspan>
<tspan dy="40em" fill="#406183" font-size="3.441666666666667" x="2" y="8.67004">● REVIEW OF SHOP DRAWINGS DOES NOT CONSTITUTE THE APPROVAL OF SAFETY REQUIREMENTS AND/OR CONSTRUCTION MEAN AND METHODS.</tspan>
<tspan dy="41em" fill="#406183" font-size="3.441666666666667" x="2" y="8.67004">● THE PRESENCE OF THE ARCHITECT ON SITE DOES NOT CONSTITUTE APPROVAL OF THE WORK. THE CONTRACTOR SHALL CALL THE ARCHITECTS</tspan>
<tspan dy="42em" fill="#406183" font-size="3.441666666666667" x="2" y="8.67004">ATTENTION TO ANYTHING SPECIFICALLY NEEDS THE ARCHITECTS APPROVAL.</tspan>
<tspan dy="43em" fill="#406183" font-size="3.441666666666667" x="2" y="8.67004">● ONLY ARCHITECTURAL AND STRUCTURAL DRAWINGS HAVE BEEN COORDINATED WITH THE ARCHITECT. CONTRACTOR SHALL NOTIFY ARCHITECT OF</tspan>
<tspan dy="44em" fill="#406183" font-size="3.441666666666667" x="2" y="8.67004">ANY WORK OUTSIDE THESE SCOPES (M/E/P, FOR EXAMPLE) THAT INTERFERES WITH THIS ARCH/STRUCT DRAWING SET.</tspan>
<tspan dy="45em" fill="#406183" font-size="3.441666666666667" x="2" y="8.67004">● GENERAL CONTRACTOR TO EDUCATE THE OWNER ON THE OPERATION AND MAINTENANCE OF ALL INSTALLED PRODUCT AND/OR EQUIPMENT.</tspan>
<tspan dy="46em" fill="#406183" font-size="3.441666666666667" x="2" y="8.67004">● PRIOR TO SUBSTANTIAL COMPLETION, THE CONTRACTOR SHALL CLEAN SITE AND DELIVER ALL REQUIRED GUARANTEES, LIEN WAITERS AND</tspan>
<tspan dy="47em" fill="#406183" font-size="3.441666666666667" x="2" y="8.67004">MAINTENANCE MANUALS</tspan>
<tspan dy="48em" fill="#406183" font-size="3.441666666666667" x="2" y="8.67004">● ARCHITECT NOT RESPONSIBLE FOR THE EXPLORATION, PRESENCE, HANDLING, AND/OR ADVERSE EXPOSURE OF ANY HAZARDOUS MATERIALS, IN</tspan>
<tspan dy="49em" fill="#406183" font-size="3.441666666666667" x="2" y="8.67004">ANY FROM. INCLUDING, BUT NOT LIMITED TO ASBESTOS PRODUCTS, POLYCHLORINATED BIPHENYL (PCB) OR OTHER TOXIC SUBSTANCES.</tspan>
<tspan dy="50em" fill="#406183" font-size="3.441666666666667" x="2" y="8.67004">● ALL EXTERIOR STRUCTURAL STEEL SHALL BE HOT DIPPED GALVANIZED. ALL NOTCHING, DRILLING, WELDING AND BENDING DONE PRIOR TO</tspan>
<tspan dy="51em" fill="#406183" font-size="3.441666666666667" x="2" y="8.67004">DIPPING.</tspan>
<tspan dy="52em" fill="#406183" font-size="3.441666666666667" x="2" y="8.67004">● ANY PRODUCT OR MATERIALS THAT ARE NOT CALLED OUT IN THE DRAWINGS, BUT REQUIRED FOR PROPER INSTALLATION AND PERFORMANCE OF</tspan>
<tspan dy="53em" fill="#406183" font-size="3.441666666666667" x="2" y="8.67004">THE WORK, SHALL BE PROVIDED BY THE CONTRACTOR.</tspan>
<tspan dy="54em" fill="#406183" font-size="3.441666666666667" x="2" y="8.67004">● THE CONTRACTOR TO PROVIDE ALL THE NECESSARY BLOCKING AND/OR STRUCTURAL SUPPORT REQUIRE TO PROPERLY INSTALL MOUNTED</tspan>
<tspan dy="55em" fill="#406183" font-size="3.441666666666667" x="2" y="8.67004">ASSEMBLIES, INCLUDED BY NOT LIMITED TO GRAB BARS, PLUMBING FIXTURES, MILLWORK AND CASEWORK.</tspan>
<tspan dy="56em" fill="#406183" font-size="3.441666666666667" x="2" y="8.67004">● MAINTAIN INGRESS AND EGRESS TO THE PROJECT SITE DURING CONSTRUCTION</tspan>
<tspan dy="57em" fill="#406183" font-size="3.441666666666667" x="2" y="8.67004">● ALL LUMBER ASSUMED TO BE SYP NO. 2 OR GREATER</tspan>
<tspan dy="58em" fill="#406183" font-size="3.441666666666667" x="2" y="8.67004">● ANY NEW OR MODIFIED FIRE ALARMS TO INTEGRATE WITH EXISTING FIRE ALARM ON THE PREMISES.</tspan>
</text>