2.2 KiB
2.2 KiB
Floor Flatness and Levelness Specifications
Overall Flatness and Levelness (SOFF / SOFL)
- The specified overall flatness (SOFF) and overall levelness (SOFL) values shall conform to the table below, based on the floor surface classification and slab category:
| Classification | SOFF | SOFL | Typical Applicability |
|---|---|---|---|
| A. Conventional | 20 | 15 | Nonpublic areas, mechanical rooms, slabs with thick-set tile or topping, parking structures |
| B. Moderately Flat | 25 | 20 | Carpeted areas |
| C. Flat | 35 | 25 | Industrial slabs, exposed slabs in public spaces, slabs to receive thin-set flooring |
| D. Very Flat | 45 | 35 | Ice or roller rinks, gymnasium floors scheduled to receive wood playing floors |
| E. Super Flat | 60 | 40 | Movie or television studios |
Minimum Local Flatness and Levelness (MLFF / MLFL)
- Minimum local flatness (MLFF) and levelness (MLFL) shall be 3/5 of the SOFF and SOFL values, unless noted otherwise.
- For industrial slabs, MLFF = 23 and MLFL = 17.
- The MLFF and MLFL values apply to the smallest areas defined by:
- Column lines and half-column lines, or
- Construction and contraction joints, whichever results in smaller areas.
Applicability of Tolerances
- SOFL and MLFL tolerances apply only to:
- Level slabs-on-ground, or
- Level, uncambered suspended slabs that are shored to prevent deflection from placement until measurement.
Sloped Slabs
- Slabs specified to slope shall have a tolerance of ±3/8" in 10 feet at any point from the specified slope.