2917_International_Ln/Open/Models/BlenderBIM/schedules/GENERAL NOTES.svg
2024-09-12 10:30:13 -05:00

166 lines
17 KiB
XML
Raw Permalink Blame History

This file contains ambiguous Unicode characters

This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.

<?xml version="1.0" encoding="utf-8" ?>
<svg xmlns="http://www.w3.org/2000/svg" xmlns:ev="http://www.w3.org/2001/xml-events" xmlns:xlink="http://www.w3.org/1999/xlink" baseProfile="full" height="360.26953999999995mm" id="root" version="1.1" viewBox="0 0 185.25083999999998 360.26953999999995" width="185.25083999999998mm">
<defs>
<style type="text/css"><![CDATA[/*
* BlenderBIM Add-on - OpenBIM Blender Add-on
* Copyright (C) 2020, 2021 Dion Moult <dion@thinkmoult.com>
*
* This file is part of BlenderBIM Add-on.
*
* BlenderBIM Add-on is free software: you can redistribute it and/or modify
* it under the terms of the GNU General Public License as published by
* the Free Software Foundation, either version 3 of the License, or
* (at your option) any later version.
*
* BlenderBIM Add-on is distributed in the hope that it will be useful,
* but WITHOUT ANY WARRANTY, without even the implied warranty of
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
* GNU General Public License for more details.
*
* You should have received a copy of the GNU General Public License
* along with BlenderBIM Add-on. If not, see <http://www.gnu.org/licenses/>.
*/
/**
* You may copy this `schedule.css` template alongside your input schedule
* document with the same filename. For example if you have a schedule called
* `door_types.ods`, you can create a `door_types.css` in the same folder to
* style that schedule.
*/
/**
* If you specify a font size in CSS, such as text { font-size: 5; }, all fonts
* will be overriden to match that size.
*
* If your CSS, ODS, XLSX does not specify a font size, the variables below
* will specify the default font size.
*
* If your ODS, XLSX does specify a font size, they will scale linearly based
* on the variables below.
*/
:root {
/* --font-size-pt: 10; */
/* --font-size-px: 3; */
--font-width: 0.75;
}
text.schedule,
tspan.schedule {
/* 2.5mm */
fill: #2c5573 !important;
stroke: none !important;
font-family: "Century Gothic", "OpenGost Type B TT", "DejaVu Sans Condensed",
"Liberation Sans", "Arial Narrow", "Arial" !important;
font-size:3.7px !important;
}
.border {
stroke: #2c5573;
stroke-width: 0.3;
fill: none !important;
}
]]></style>
</defs>
<rect class="border" height="6.670039999999999" style="fill: #ffffff;" width="183.25083999999998" x="1" y="1"/>
<text class="schedule" dominant-baseline="middle" fill="#000000" font-size="0" text-anchor="start">
<tspan class="schedule" dy="0.0em" fill="#000000" font-size="3.0" x="2" y="4.33502">GENERAL NOTES</tspan>
</text>
<rect class="border" height="351.5995" style="fill: #ffffff;" width="183.25083999999998" x="1" y="7.670039999999999"/>
<text class="schedule" dominant-baseline="hanging" fill="#000000" font-size="0" text-anchor="start">
<tspan class="schedule" dy="0em" fill="#000000" font-size="3.0" x="2" y="8.67004">● THE MECHANICAL (HVAC), ELECTRICAL, PLUMBING, FIRE PROTECTION, AND FIRE ALARM</tspan>
<tspan class="schedule" dy="1em" fill="#000000" font-size="3.0" x="2" y="8.67004">SYSTEMS WILL BE DESIGNED AND CONSTRUCTED USING THE DESIGN-BUILD DELIVERY METHOD.</tspan>
<tspan class="schedule" dy="2em" fill="#000000" font-size="3.0" x="2" y="8.67004">THESE SPECIFIC DETAILS ARE NOT PROVIDED IN THESE DOCUMENTS. IT IS THE</tspan>
<tspan class="schedule" dy="3em" fill="#000000" font-size="3.0" x="2" y="8.67004">RESPONSIBILITY OF THE M/E/P/FP/A CONTRACTOR TO COORDINATE WITH THE GENERAL</tspan>
<tspan class="schedule" dy="4em" fill="#000000" font-size="3.0" x="2" y="8.67004">CONTRACTOR AND UTILIZE THESE DRAWINGS TO GUIDE THE FINAL DESIGN OF THEIR SYSTEMS.</tspan>
<tspan class="schedule" dy="5em" fill="#000000" font-size="3.0" x="2" y="8.67004">ANY CHANGES TO THE STRUCTURE OR ARCHITECTURAL FEATURES MUST BE COMMUNICATED TO</tspan>
<tspan class="schedule" dy="6em" fill="#000000" font-size="3.0" x="2" y="8.67004">THE ARCHITECT IN ADVANCE.</tspan>
<tspan class="schedule" dy="7em" fill="#000000" font-size="3.0" x="2" y="8.67004">● GENERAL CONTRACTOR RESPONSIBLE FOR ALL FEES ASSOCIATED WITH PERMITS,</tspan>
<tspan class="schedule" dy="8em" fill="#000000" font-size="3.0" x="2" y="8.67004">APPLICATIONS, TAXES, AND CERTIFICATES OF INSPECTIONS.</tspan>
<tspan class="schedule" dy="9em" fill="#000000" font-size="3.0" x="2" y="8.67004">● ANY CONSTRUCTION THAT DEVIATES FROM THE DRAWING IS UNAUTHORIZED, IF NOT</tspan>
<tspan class="schedule" dy="10em" fill="#000000" font-size="3.0" x="2" y="8.67004">AUTHORIZED BY THE ARCHITECT. IN SUCH AN EVENT, CONTRACTOR IS RESPONSIBLE FOR ANY</tspan>
<tspan class="schedule" dy="11em" fill="#000000" font-size="3.0" x="2" y="8.67004">REWORK THAT MIGHT BE REQUIRED.</tspan>
<tspan class="schedule" dy="12em" fill="#000000" font-size="3.0" x="2" y="8.67004">● CONTRACTOR IS RESPONSIBLE FOR ALL THE RULES/REGULATIONS OF THE AUTHORITY HAVING</tspan>
<tspan class="schedule" dy="13em" fill="#000000" font-size="3.0" x="2" y="8.67004">JURISDICTION. INCLUDED, BUT NOT LIMITED TO ALL CITY, TOWNSHIP, COUNTY, STATE, AND</tspan>
<tspan class="schedule" dy="14em" fill="#000000" font-size="3.0" x="2" y="8.67004">FEDERAL CODES, STATUTES, AND ORDINANCES.</tspan>
<tspan class="schedule" dy="15em" fill="#000000" font-size="3.0" x="2" y="8.67004">● CONTRACTORS SHALL VISIT THE SITE PRIOR TO CONSTRUCTION TO DETERMINE HOW NEW</tspan>
<tspan class="schedule" dy="16em" fill="#000000" font-size="3.0" x="2" y="8.67004">CONSTRUCTION IS COMPATIBLE WITH EXISTING CONDITIONS.</tspan>
<tspan class="schedule" dy="17em" fill="#000000" font-size="3.0" x="2" y="8.67004">● CONTRACTOR TO NOTIFY ARCHITECT IF THERE ARE ANY OMISSIONS, CONFLICTS, OR</tspan>
<tspan class="schedule" dy="18em" fill="#000000" font-size="3.0" x="2" y="8.67004">DISCREPANCIES IN THE DRAWINGS BEFORE ANY CONSTRUCTION TAKES PLACE. A FAILURE TO</tspan>
<tspan class="schedule" dy="19em" fill="#000000" font-size="3.0" x="2" y="8.67004">SO WILL RESULT IN THE CONTRACTOR RESPONSIBLE FOR ANY REWORK.</tspan>
<tspan class="schedule" dy="20em" fill="#000000" font-size="3.0" x="2" y="8.67004">● CONTRACTOR RESPONSIBLE FOR VERIFYING ALL DIMENSIONS AND TAKEOFFS BEFORE BIDDING</tspan>
<tspan class="schedule" dy="21em" fill="#000000" font-size="3.0" x="2" y="8.67004">AND/OR ORDERING MATERIALS. CONTRACTOR WILL NOTIFY ARCHITECT IF THERE ANY DRAWING</tspan>
<tspan class="schedule" dy="22em" fill="#000000" font-size="3.0" x="2" y="8.67004">CONFLICTS AND AWAIT DIRECTION BEFORE COMMENCING.</tspan>
<tspan class="schedule" dy="23em" fill="#000000" font-size="3.0" x="2" y="8.67004">● DO NOT SCALE THE DRAWINGS.</tspan>
<tspan class="schedule" dy="24em" fill="#000000" font-size="3.0" x="2" y="8.67004">● ALL THROUGH AND MEMBRANE PENETRATIONS AT ALL FIRE/SMOKE RATED</tspan>
<tspan class="schedule" dy="25em" fill="#000000" font-size="3.0" x="2" y="8.67004">PARTITIONS/CEILINGS/FLOORS TO BE SEALED WITH A CODE COMPLIANT, U.L. APPROVED FIRE</tspan>
<tspan class="schedule" dy="26em" fill="#000000" font-size="3.0" x="2" y="8.67004">STOP.</tspan>
<tspan class="schedule" dy="27em" fill="#000000" font-size="3.0" x="2" y="8.67004">● GENERAL CONTRACTOR TO COORDINATE THE SIZE/LOCATION OF ANY ACCESS PANELS AND/OR</tspan>
<tspan class="schedule" dy="28em" fill="#000000" font-size="3.0" x="2" y="8.67004">CLEAN OUTS WITH THE M/E/P CONTRACTOR AND ARCHITECT.</tspan>
<tspan class="schedule" dy="29em" fill="#000000" font-size="3.0" x="2" y="8.67004">● ALL CONTRACTORS AND VENDORS TO FAMILIARIZE THEMSELVES WITH THE ENTIRE DRAWING</tspan>
<tspan class="schedule" dy="30em" fill="#000000" font-size="3.0" x="2" y="8.67004">SET, AS REQUIRED INFORMATION MAY BE ON MULTIPLE SHEETS AND ALTERNATE DISCIPLINES.</tspan>
<tspan class="schedule" dy="31em" fill="#000000" font-size="3.0" x="2" y="8.67004">● ANY FURNITURE SHOWN IS FOR REFERENCE ONLY.</tspan>
<tspan class="schedule" dy="32em" fill="#000000" font-size="3.0" x="2" y="8.67004">● CONTRACTORS SHALL BE RESPONSIBLE FOR REPAIRING ANY PROPERTY DAMAGE THAT MAY</tspan>
<tspan class="schedule" dy="33em" fill="#000000" font-size="3.0" x="2" y="8.67004">HAVE RESULTED FROM THEIR WORK.</tspan>
<tspan class="schedule" dy="34em" fill="#000000" font-size="3.0" x="2" y="8.67004">● OWNER RESPONSIBLE FOR ANY WORK NOT SPECIFICALLY CALLED OUT IN THE DRAWINGS.</tspan>
<tspan class="schedule" dy="35em" fill="#000000" font-size="3.0" x="2" y="8.67004">● ANY CHANGE THAT RESULTS IN ADDITIONAL COST/TIME MUST TO APPROVED BY THE</tspan>
<tspan class="schedule" dy="36em" fill="#000000" font-size="3.0" x="2" y="8.67004">OWNER/ARCHITECT PRIOR TO CONSTRUCTION.</tspan>
<tspan class="schedule" dy="37em" fill="#000000" font-size="3.0" x="2" y="8.67004">● DETAILS ARE TO BE INTERPRETED AS TYPICAL. THAT IS, UNLESS SPECIFICALLY CALLED</tspan>
<tspan class="schedule" dy="38em" fill="#000000" font-size="3.0" x="2" y="8.67004">OUT OTHERWISE, THE DETAIL IS TO BE APPLIED TO SIMILAR CONDITIONS THROUGHOUT THE</tspan>
<tspan class="schedule" dy="39em" fill="#000000" font-size="3.0" x="2" y="8.67004">PROJECT.</tspan>
<tspan class="schedule" dy="40em" fill="#000000" font-size="3.0" x="2" y="8.67004">● ALL EXTERIOR FLATWORK AROUND THE BUILDING TO SLOPE A MINIMUM OF 2% AWAY FROM</tspan>
<tspan class="schedule" dy="41em" fill="#000000" font-size="3.0" x="2" y="8.67004">THE BUILDING.</tspan>
<tspan class="schedule" dy="42em" fill="#000000" font-size="3.0" x="2" y="8.67004">● ANY PENETRATIONS IN THE EXTERIOR ENVELOPE TO BE SEALED TO PREVENT ANY AIR/WATER</tspan>
<tspan class="schedule" dy="43em" fill="#000000" font-size="3.0" x="2" y="8.67004">LEAKAGE PER IBC CODE REQUIREMENTS.</tspan>
<tspan class="schedule" dy="44em" fill="#000000" font-size="3.0" x="2" y="8.67004">● ON THE DRAWINGS, NOTIFY ARCHITECT OF ANY PENETRATIONS IN THE EXTERIOR WALL THAT</tspan>
<tspan class="schedule" dy="45em" fill="#000000" font-size="3.0" x="2" y="8.67004">ARE LARGER THAN 12&quot;X12&quot;</tspan>
<tspan class="schedule" dy="46em" fill="#000000" font-size="3.0" x="2" y="8.67004">● UNLESS OTHERWISE NOTED, SLOPE FLOOR 2% TOWARD ANY DRAINS INDICATED ON THE</tspan>
<tspan class="schedule" dy="47em" fill="#000000" font-size="3.0" x="2" y="8.67004">DRAWINGS.</tspan>
<tspan class="schedule" dy="48em" fill="#000000" font-size="3.0" x="2" y="8.67004">● CONTRACTOR SHALL KEEP THE CONSTRUCTION CLEANREMOVING ANY ACCUMULATION OF</tspan>
<tspan class="schedule" dy="49em" fill="#000000" font-size="3.0" x="2" y="8.67004">DEBRIS AND/OR UNUSED EQUIPMENT.</tspan>
<tspan class="schedule" dy="50em" fill="#000000" font-size="3.0" x="2" y="8.67004">● CONTRACTOR TO BE RESPONSIBLE FOR THE COLLECTION, TRANSPORT AND DISPOSAL OF ALL</tspan>
<tspan class="schedule" dy="51em" fill="#000000" font-size="3.0" x="2" y="8.67004">CONSTRUCTION WASTE.</tspan>
<tspan class="schedule" dy="52em" fill="#000000" font-size="3.0" x="2" y="8.67004">● CONTRACTORS RESPONSIBLE FOR ANY TEMPORARY SHORING THAT MIGHT BE NECESSARY</tspan>
<tspan class="schedule" dy="53em" fill="#000000" font-size="3.0" x="2" y="8.67004">DURING CONSTRUCTION. ALL SHORING TO BE DESIGNED BY A LICENSED STRUCTURAL ENGINEER</tspan>
<tspan class="schedule" dy="54em" fill="#000000" font-size="3.0" x="2" y="8.67004">RETAINED BY THE CONTRACTOR.</tspan>
<tspan class="schedule" dy="55em" fill="#000000" font-size="3.0" x="2" y="8.67004">● GENERAL CONTRACTOR TO VERIFY WITH THE M/E/P CONTRACTORS ALL PIPE/DUCT LOCATION</tspan>
<tspan class="schedule" dy="56em" fill="#000000" font-size="3.0" x="2" y="8.67004">PRIOR TO FRAMING.</tspan>
<tspan class="schedule" dy="57em" fill="#000000" font-size="3.0" x="2" y="8.67004">● MANUFACTURED MATERIAL/EQUIPMENT TO BE INSTALLED PER MANUFACTURERS</tspan>
<tspan class="schedule" dy="58em" fill="#000000" font-size="3.0" x="2" y="8.67004">REQUIREMENTS.</tspan>
<tspan class="schedule" dy="59em" fill="#000000" font-size="3.0" x="2" y="8.67004">● CONTRACTOR TO PROTECT ANY EXPOSED CONCRETE THAT IS MEANT TO BE A FINISHED</tspan>
<tspan class="schedule" dy="60em" fill="#000000" font-size="3.0" x="2" y="8.67004">SURFACE.</tspan>
<tspan class="schedule" dy="61em" fill="#000000" font-size="3.0" x="2" y="8.67004">● GENERAL CONTRACTOR TO PROVIDE ARCHITECT AT LEAST (2) WEEKS WHEN REVIEWING ANY</tspan>
<tspan class="schedule" dy="62em" fill="#000000" font-size="3.0" x="2" y="8.67004">SHOP DRAWINGS AND/OR SUBSTITUTION REQUESTS.</tspan>
<tspan class="schedule" dy="63em" fill="#000000" font-size="3.0" x="2" y="8.67004">● REVIEW OF SHOP DRAWINGS DOES NOT CONSTITUTE THE APPROVAL OF SAFETY REQUIREMENTS</tspan>
<tspan class="schedule" dy="64em" fill="#000000" font-size="3.0" x="2" y="8.67004">AND/OR CONSTRUCTION MEAN AND METHODS.</tspan>
<tspan class="schedule" dy="65em" fill="#000000" font-size="3.0" x="2" y="8.67004">● THE PRESENCE OF THE ARCHITECT ON SITE DOES NOT CONSTITUTE APPROVAL OF THE WORK.</tspan>
<tspan class="schedule" dy="66em" fill="#000000" font-size="3.0" x="2" y="8.67004">THE CONTRACTOR SHALL CALL THE ARCHITECTS ATTENTION TO ANYTHING SPECIFICALLY</tspan>
<tspan class="schedule" dy="67em" fill="#000000" font-size="3.0" x="2" y="8.67004">NEEDS THE ARCHITECTS APPROVAL.</tspan>
<tspan class="schedule" dy="68em" fill="#000000" font-size="3.0" x="2" y="8.67004">● ONLY ARCHITECTURAL AND STRUCTURAL DRAWINGS HAVE BEEN COORDINATED WITH THE</tspan>
<tspan class="schedule" dy="69em" fill="#000000" font-size="3.0" x="2" y="8.67004">ARCHITECT. CONTRACTOR SHALL NOTIFY ARCHITECT OF ANY WORK OUTSIDE THESE SCOPES</tspan>
<tspan class="schedule" dy="70em" fill="#000000" font-size="3.0" x="2" y="8.67004">(M/E/P, FOR EXAMPLE) THAT INTERFERES WITH THIS ARCH/STRUCT DRAWING SET.</tspan>
<tspan class="schedule" dy="71em" fill="#000000" font-size="3.0" x="2" y="8.67004">● GENERAL CONTRACTOR TO EDUCATE THE OWNER ON THE OPERATION AND MAINTENANCE OF ALL</tspan>
<tspan class="schedule" dy="72em" fill="#000000" font-size="3.0" x="2" y="8.67004">INSTALLED PRODUCT AND/OR EQUIPMENT.</tspan>
<tspan class="schedule" dy="73em" fill="#000000" font-size="3.0" x="2" y="8.67004">● PRIOR TO SUBSTANTIAL COMPLETION, THE CONTRACTOR SHALL CLEAN SITE AND DELIVER</tspan>
<tspan class="schedule" dy="74em" fill="#000000" font-size="3.0" x="2" y="8.67004">ALL REQUIRED GUARANTEES, LIEN WAITERS AND MAINTENANCE MANUALS</tspan>
<tspan class="schedule" dy="75em" fill="#000000" font-size="3.0" x="2" y="8.67004">● ARCHITECT NOT RESPONSIBLE FOR THE EXPLORATION, PRESENCE, HANDLING, AND/OR</tspan>
<tspan class="schedule" dy="76em" fill="#000000" font-size="3.0" x="2" y="8.67004">ADVERSE EXPOSURE OF ANY HAZARDOUS MATERIALS, IN ANY FROM. INCLUDING, BUT NOT</tspan>
<tspan class="schedule" dy="77em" fill="#000000" font-size="3.0" x="2" y="8.67004">LIMITED TO ASBESTOS PRODUCTS, POLYCHLORINATED BIPHENYL (PCB) OR OTHER TOXIC</tspan>
<tspan class="schedule" dy="78em" fill="#000000" font-size="3.0" x="2" y="8.67004">SUBSTANCES.</tspan>
<tspan class="schedule" dy="79em" fill="#000000" font-size="3.0" x="2" y="8.67004">● ALL EXTERIOR STRUCTURAL STEEL SHALL BE HOT DIPPED GALVANIZED. ALL NOTCHING,</tspan>
<tspan class="schedule" dy="80em" fill="#000000" font-size="3.0" x="2" y="8.67004">DRILLING, WELDING AND BENDING DONE PRIOR TO DIPPING.</tspan>
<tspan class="schedule" dy="81em" fill="#000000" font-size="3.0" x="2" y="8.67004">● ANY PRODUCT OR MATERIALS THAT ARE NOT CALLED OUT IN THE DRAWINGS, BUT REQUIRED</tspan>
<tspan class="schedule" dy="82em" fill="#000000" font-size="3.0" x="2" y="8.67004">FOR PROPER INSTALLATION AND PERFORMANCE OF THE WORK, SHALL BE PROVIDED BY THE</tspan>
<tspan class="schedule" dy="83em" fill="#000000" font-size="3.0" x="2" y="8.67004">CONTRACTOR.</tspan>
<tspan class="schedule" dy="84em" fill="#000000" font-size="3.0" x="2" y="8.67004">● THE CONTRACTOR TO PROVIDE ALL THE NECESSARY BLOCKING AND/OR STRUCTURAL SUPPORT</tspan>
<tspan class="schedule" dy="85em" fill="#000000" font-size="3.0" x="2" y="8.67004">REQUIRE TO PROPERLY INSTALL MOUNTED ASSEMBLIES, INCLUDED BY NOT LIMITED TO GRAB</tspan>
<tspan class="schedule" dy="86em" fill="#000000" font-size="3.0" x="2" y="8.67004">BARS, PLUMBING FIXTURES, MILLWORK AND CASEWORK.</tspan>
<tspan class="schedule" dy="87em" fill="#000000" font-size="3.0" x="2" y="8.67004">● MAINTAIN INGRESS AND EGRESS TO THE PROJECT SITE DURING CONSTRUCTION</tspan>
<tspan class="schedule" dy="88em" fill="#000000" font-size="3.0" x="2" y="8.67004">● ALL LUMBER ASSUMED TO BE SYP NO. 2 OR GREATER</tspan>
<tspan class="schedule" dy="89em" fill="#000000" font-size="3.0" x="2" y="8.67004">● ANY NEW OR MODIFIED FIRE ALARMS TO INTEGRATE WITH EXISTING FIRE ALARM ON THE</tspan>
<tspan class="schedule" dy="90em" fill="#000000" font-size="3.0" x="2" y="8.67004">PREMISES.</tspan>